20. Clean “water distributor system” by cleaning 

solution then rinse  by fresh water 

 

 

 

21. Clean water reservoir and its covers by cleaning 

solution then rinse by fresh water 

 

 

 

 
 

22. Carefully reinstall all removed parts 

 

23. Turn the power 

ON

 by main switch and 

OPEN

 

the water tap 
 

24. Push the 

RESET BUTTON

 for  6-8 seconds till  

 

 

 

25. BIN FULL YELLOW LED starts slowly blinking 

(this bring the unit at 

Cleaning cycle stand by 

MODE

 
         

POWER

OPER.

BIN

FULL

ALARM

ALARM

HI

PRESS.

RE-SET

 

 

26. Pour following quantity of cleaner inside water 

sump 

 

SV 145-205: 

300 ml 

SV 225-325: 

400 ml

 

SV 395-545:  

500 ml

 

 

 

 
27. Push again the 

RESET BUTTON

 for a while 

 

 

 
 
28. The 

WASH YELLOW LED

 starts to blink 

FAST

 

and the machine enter in the Cleaning Cycle 

 

POWER

OPER.

BIN

FULL

ALARM

ALARM

HI

PRESS.

RE-SET

 

  

  

…..the water pump starts to operate while the water 
inlet valve will be energized till the fill up of the water 
sump 
 

 

 

O

O

N

N

 

 

 

Содержание SV 145

Страница 1: ...RST DE SCALE AND AFTER PROPER WASHING AND RINSING DO THE SANITATION WARNING When using any chemical protection of hands and eyes should be worn NOTE De scaling is recommended every 6 months in average...

Страница 2: ...ary container or discard it If routine sanitizing is due the ice machine should be switched off during evening closing procedures to minimize waste during next morning sanitizing procedures 4 Remove t...

Страница 3: ...t off to right hand thus to release the same from its bottom plastic bracket 11 Lift up and remove silicon cover 12 Cut water pump hose clamp and disconnect hose from its fitting 13 Push water level s...

Страница 4: ...ater pump off from its seat 17 Push the two water sump holding brackets and withdraw water reservoir from its seat 18 Using gloves prepare the cleaning solution by diluting in a plastic bucket two lit...

Страница 5: ...D starts slowly blinking this bring the unit at Cleaning cycle stand by MODE POWER OPER BIN FULL ALARM ALARM HI PRESS RE SET 26 Pour following quantity of cleaner inside water sump SV 145 205 300 ml S...

Страница 6: ...e water drain valve for 40 seconds to drain out all remained water then both are de energized while water inlet valve remains energized open 33 Once water reservoir is filled up by water the water pum...

Страница 7: ...by 1 of Amuchina sanitizer 41 Open the Ice storage bin 42 Fill up by mixed solution at 40 a spray bottle then spray the same to all bin internal wall area 43 With proper brush wipe all over bin insid...

Отзывы: