SIM2 DOMINO 55M
RS-232C CONTROL SPECIFICATIONS
8
9
10
11
12
13
14
15
16
17
18
19
20
Op Type
Op ID
01
00
Op Target
00
00
Value
00
00
21
22
23
24
25
26
27
28
29
30
31
32
00
00
00
00
00
00
00
00
00
00
00
00
Get Codes
Get Commands may be used to get the current value of DOMINO 55M parameters.
The response to a correct Get Command consists of 33 byte packet, where Byte Number 11 contains the
Validation Code (
01
) and bytes Number 17 and Number 18 the requested value (the least-significant byte of
the value being sent first). Of course CRC (bytes number 6 and 7) has been altered accordingly.
0
1
2
3
4
5
6
7
1E BE EF
Packet Type
Packet Payload Size
Packet Checksum (CRC)
8
9
10
11
12
13
14
15
16
17
18
19
20
Op Type
Op ID
01
00
Op Target
00
00
Req Value
00
00
21
22
23
24
25
26
27
28
29
30
31
32
00
00
00
00
00
00
00
00
00
00
00
00
Get Codes:
BRIGHTNESS
BE EF 03 19 00 52 2A 02 00 08 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(1)
CONTRAST
BE EF 03 19 00 C7 77 02 01 08 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(1)
COLOR
BE EF 03 19 00 38 93 02 02 08 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(2)
TINT
BE EF 03 19 00 AD CE 02 03 08 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(3)
COLOR TEMPERATURE
BE EF 03 19 00 9D 0B 02 C2 09 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(4)
GAMMA
BE EF 03 19 00 13 25 02 27 08 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(5)
MEMORY
BE EF 03 19 00 5E D5 02 27 09 00 00 01 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(6)
10