Safety Precautions

During operation observe the safety warnings and precautions.

Prior to an inspection please check:

• 

Calibration validity date

• 

System for damage, including probe, 
connectors and umbilical 

• 

All connectors are secure

• 

Batteries are charged

• 

Clean and apply silicon oil to the probe 

• 

Apply silicon oil to the probe pad

Scorpion2 Quick Start Guide

READ AND UNDERSTAND THE USER MANUAL

The Swift and Scorpion2 system are designed for a specific use.  Using the Swift or 
Scorpion2 system outside of its intended use is dangerous. Severe injury or death 
could result. Read and understand the user manual before use.

TRANSPORTATION

It is the users responsibility to make sure that the transport safety precautions are in 
accordance with the local department of transportation (or equivalent governing 
body) rules and regulations. The system contains lithium-ion batteries and magnetic 
materials. See user manual for more details

DO NOT OPERATE WITHOUT TETHER

Keep the area below an operating crawler clear at all times.  A NO ENTRY ZONE must 
be clearly marked and cordoned off directly below the crawler. The NO ENTRY ZONE 
must be a minimum of 6m (20 ft) in all directions from the point below the crawler.

1. 

Remove the Swift, Scorpion2 and umbilical 
cable reel from their transit cases.

2. 

Insert batteries into the Swift and Scorpion2.

3. 

Unwind the umbilical cable to the required 
length. Failure to do so could twist the 
cable.

4. 

Connect the umbilical connectors to the 
rear of the Scorpion2. Observe connector 
color coding. 

5. 

Attach both umbilical tether clips to the 
anchor points on the rear handle.

6. 

Unwind the short section of umbilical from 
the side of the reel.

7. 

Connect the umbilical connectors to Swift. 
Observe connector color coding. 

8. 

Attach a suitable tether line to the 
Scorpion2 crawler anchor points.

Connecting Scorpion2 to Swift

Pre-Inspection 

MAGNETIC MATERIAL

The wheels of the crawler and the probe holder contain strong magnets that produce 
an extremely strong magnetic field which may cause failure or permanent damage 
to items such as watches, memory devices, and other electronics devices. 

WARNING FINGER TRAP

Tools, magnets, and metal objects can cut, pinch, or entrap hands and fingers. 
HANDLE WITH CARE. 

Color

Status

Troubleshoot

          Green

Ready

          Flashing Red

Awaiting Swift comms

Check umbilical connectors (allow 1 min to 
establish a connection)

          Off

No Power

Check batteries and emergency stop

Tether points

Umbilical 
anchor points

Encoder

Battery 

compartment

Probe 

assembly

Wear 

pads

Probe

Silicon Oil

LEDsatus indicator

LED Status Indicator

PACEMAKER

People with pacemakers or ICD’s must stay at least 2 m (6.5 ft) away.