Silvertel EVALAg7100 Скачать руководство пользователя страница 7

Ag7100-Ag6100 Evaluation Board User Manual 

6

4.3  Ag6100 Output Power 

The output power from the Ag6100 can be connected to the centre taps of T1 using the 
links – LK1 & LK2, see Figure 6. 

 

With the links in position “a”, the Ag6100 output is connected to centre taps of the pairs 
4 & 5 (positive) and 7 & 8 (negative). 

 

With the links in position “b”, the Ag6100 output is connected to centre taps of the pairs 
1 & 2 (positive) and 3 & 6 (negative). 

 

 

Figure 6: Ag6100 Output Power Links 

 

4.4  Ag7100 Output Adjustment 

The Ag7100 output is set to 57V by default. This can be adjusted down to its minimum 
of 48V by connecting LK3, see Figure 7. 

 

 

Figure 7: Ag7100 Output Adjustment  

 

 