background image

06

(1)T3: Power good signal turn on delay time (100ms~500ms)
(2)T2: Rise time(0.1~20ms)
(3)T6: Hold up time (75%Load 16ms)

When the power loss its input power, it shall maintain 16ms in regulation limit at normal 
input voltage and 75% full load  (AC:115V/60Hz or 230V/50Hz)

The power supply designed to meet UL 60950.

4.2 Hold up time

5.1 Operation

5. ENVIRONMENT

6.1 Underwriters Laboratory (UL) recognition.

6. SAFETY

7.1 ELECTROSTATIC DISCHARGE (ESD) -  IEC 61000 – 4 - 2

2008

7.2 ELECTRICAL FAST TRANSIENT / BURST ( EFT/B) – IEC 61000 – 4 - 4

2012

7.3 SURGE – IEC 61000 – 4 - 5

2005

7.4 POWER FREQUENCY MAGNETIC FIELD – IEC 61000 – 4 - 8

2009

7.5 VOLTAGE DIPS – IEC 61000 – 4 - 11

2004

7.6 RADIATED SUSCEPTIBILTY – IEC 61000 – 4 – 3

2006+A1

2007+A2

2010

7.7 CONDUCTED SUSCEPTIBILTY – IEC 61000 – 4 - 6

2008

7.8 VOLTAGE FLUCTATION -  EN 61000 – 3 – 3

2008

7. ELECTROMAGNETIC COMPATIBILITY (EMC)

Temperature

Relative Humidity

0 to 40C

10 to 90%, non-condensing 

o

5.2 Shipping and Storage

Temperature

Relative Humidity

-20 to 90C 

5 to 95%, non-condensing 

o

5.3 Altitude

Operating

Storage

10,000FT max
50,000FT max

Содержание ST60F-TI

Страница 1: ...ciency with 80 PLUS Titanium certification Compact design with a depth of 150mm for easy integration 100 modular cables 24 7 continuous power output with 40C operating temperature Class leading single...

Страница 2: ......

Страница 3: ...e keep this manual for future reference when upgrading or performing maintenance on your system A copy of this manual can also be downloaded from our website at Installation and system optimization gu...

Страница 4: ...le cycle AC dropout condition during repetitive ON OFF cycling of AC and over the specified temperature range Top The peak inrush current shall be less than the ratings of its critical components incl...

Страница 5: ...OUTPUT Parameter 3 3V 5V 12V 12V 5VSB Range 3 3 3 10 5 Min 3 20 4 85 11 64 13 20 4 75 Nom 3 30 5 00 12 00 12 00 5 00 Max 3 39 5 15 12 36 10 80 5 25 Unit Volts Volts Volts Volts Volts Parameter 3 3V 5...

Страница 6: ...all outputs The ripple voltage of the outputs shall be measured at the pins of the output connector when terminated in the load impedance specified in figure 1 Ripple and noise are measured at the co...

Страница 7: ...cuit condition 3 3 Over power protection The power supply will be shutdown and latch off when output power within 110 160 of rated DC output Note Assurance machine can work at low voltage full load wo...

Страница 8: ...use any damage to the power supply The power supply shall either shut down and latch off or fold back for shorting the negative rails 5VSB must be capable of being shorted indefinitely but when the sh...

Страница 9: ...C DISCHARGE ESD IEC 61000 4 2 2008 7 2 ELECTRICAL FAST TRANSIENT BURST EFT B IEC 61000 4 4 2012 7 3 SURGE IEC 61000 4 5 2005 7 4 POWER FREQUENCY MAGNETIC FIELD IEC 61000 4 8 2009 7 5 VOLTAGE DIPS IEC...

Страница 10: ...61000 3 2 Class D and the Guidelines for the Suppression of Harmonics in Appliances and General Use Equipment Class D for harmonic line current content at full rated power The demonstrated MTBF shall...

Страница 11: ......

Страница 12: ...G11226000...