05

Power supply efficiency typical 87%~90% at normal AC main voltage and 20%~100% 
load on all outputs.

2.5 Efficiency

When the logic level "PS-ON" is low, the DC outputs are to be enabled.
When the logic level is high or open collector, the DC outputs are to be disabled.

2.6 Remote ON/OFF control

The power supply shall have current limit to prevent the +3.3V,+5V,and +12V 
outputs from exceeding the values shown in the following Table.If the current 
limits are exceeded the power supply shall shutdown and latch off.

The power supply will be protected against over temperature conditions caused by 
loss of fan cooling or excessive ambient temperature. In an OTP condition the PSU 
will shutdown. When the power supply temperature drops to within specifide limits, 
the power supply shall restore power automatically. The OTP circuit must have built 
in hysteresis such that the power supply will not oscillate on and off due to temperature 
recovering condition.

3.1 Over current protection

3. PROTECTION

ST75F-G

Voltage

+3.3V

+5V

+12V

Over Current Limit (Iout limit)

30A  minimum;   50A  maximum

30A  minimum;   50A  maximum

65A  minimum;   105A  maximum

Voltage

+3.3V

+5V

+12V

Over Current Limit (Iout limit)

30A  minimum;   50A  maximum

30A  minimum;   50A  maximum

85A  minimum;   130A  maximum

ST85F-G

Voltage

+3.3V

+5V

+12V

Over Current Limit (Iout limit)

30A  minimum;   50A  maximum

30A  minimum;   50A  maximum

75A  minimum;   120A  maximum

ST1000-G

Voltage

+3.3V

+5V

+12V

Over Current Limit (Iout limit)

30A  minimum;   50A  maximum

30A  minimum;   50A  maximum

105A  minimum;  150A  maximum

ST1200-G

06

STRIDER GOLD SERIES

output 

+12 VDC

+5 VDC

+3.3 VDC

Minimum 

13.3

5.70

3.90

Nominal

15.0

6.30

4.20

Maximum

16.5

7.00

4.50

Unit

Volts

Volts

Volts

The power supply will be shutdown and latch off when output power within 105~150% 
of rated DC output.
Note: Assurance machine can work at low voltage, full load won't damage machine.

3.2 Over-power protection

The power supply will be shutdown and latch off when output power within 105~150% 
of rated DC output.
Note: Assurance machine can work at low voltage,full load won't damage machine.

3.3 Over-power protection

In an under voltage fault occurs, the supply will latch all DC outputs into a shutdown 
state when +12V,+5V & +3.3V outputs under 85% of it's maximum value.

3.4 Under voltage protection

The over voltage sense circuitry and reference shall reside in packages that are 
separate and distinct from the regulator control circuity and reference. No single 
point fault shall be able to cause a sustained over voltage condition on any or all 
outputs. The supply shall provide latch-mode over voltage protection as defined 
in Table.

3.5 Over voltage protection

An output short circuit is defined as any output impedance of less than 0.1 ohms. 
The power supply shall shut down and latch off for shorting the +3.3 VDC,+5 VDC,
or+12 VDC rails to return or any other rail. Shorts between main output rails and 
+5VSB shall not cause any damage to the power supply. The power supply shall 
either shut down and latch off or fold back for shorting the negative rails.+5VSB 
must be capable of being shorted indefinitely, but when the short is removed, the 
power supply shall recover automatically or by cycling PS_ON# .The power supply 
shall be capable of withstanding a continuous short-circuit to the output without 
damage or overstress to the unit.

3.6 Short circuit

No damage or hazardous condition should occur with all the DC output connectors 
disconnected from the load. The power supply may latch into the shutdown state.

3.7 No load operation

Содержание SST-ST1200-G

Страница 1: ...October 2010 NO G11212840 STRIDER GOLD ST1200 G ST1000 G ST85F G ST75F G The perfect balance of performance efficiency and quality ...

Страница 2: ...ut fuse bulk rectifiers and surge limiting device Parameter Vin Full range Vin Full range 1200W Vin Frequency Iin 750W Iin 850W Iin 1000W 1200W Min 90 103 47 Nom 100 240 115 240 60 50 9 5 4 8 11 5 5 12 6 Max 264 264 63 Unit VACrms VACrms Hz Arms Arms Arms 02 STRIDER GOLD SERIES 2 DC OUTPUT 2 1 DC voltage regulation 1 Maximum continuous total DC output power should not exceed 750W 2 Maximum continu...

Страница 3: ...hall not exceed 150W 3 Maximum current for 12V outputs shall be 100A 1200W 4 Maximum peak total DC output power should not exceed 1300W 5 Peak power and current loading shall be supported for a minimum of 12 second 6 When 12V is load to 28A 12V minimum load is 0 02A 2 2 4 ST1200 G Load Range Parameter 3 3V 5V 12V 12V 5VSB Min 0 3 0 3 0 1 0 0 1 Max 25 25 100 0 3 3 5 Unit Amps Amps Amps Amps Amps 04...

Страница 4: ...t Volts Volts Volts The power supply will be shutdown and latch off when output power within 105 150 of rated DC output Note Assurance machine can work at low voltage full load won t damage machine 3 2 Over power protection The power supply will be shutdown and latch off when output power within 105 150 of rated DC output Note Assurance machine can work at low voltage full load won t damage machin...

Страница 5: ...UIREMENTS The power supply designed to meet UL 1950 If applicable to sales in Japan or Europe the power supply shall meet the requirements of EN 61000 3 2 class D and the guidelines for the suppression of harmonics in appliances and general use equipment class D for harmonic line current content at full rated power 6 1 Underwriters Laboratory UL recognition The demonstrated MTBF shall be 100 000 h...

Страница 6: ...ck Black ATX 12V 4PIN 4 4PIN EPS 12V in split mode Black Black Signal GND GND Pin 1 2 Pin 3 4 Signal 12V 12V Yellow Yellow 9 2 Connectors 10 STRIDER GOLD SERIES SATA connector Orange Black Red Black Yellow Signal 3 3V COM 5V COM 12V Pin 5 4 3 2 1 8PIN PCI Express connector Yellow Yellow Yellow Black sense1 Signal 12V 12V 12V COM Pin 1 2 3 4 Pin 5 6 7 8 Signal COM COM COM COM Black Black Black Blac...