SPECIFICATION 

STRIDER GOLD SERIES 

SST-ST1200-G 
SST-ST1000-G 

SST-ST85F-G 
SST-ST75F-G 

01

ATX12V / EPS 12V Switching Power Supply

With Active PFC

80 PLUS Gold

PS/2

  This specification describes the requirements of 750W, 850W, 1000W, 1200W  
switching power supply with an stretch ATX form-factor and EPS12V, +5V standby  
voltage, remote on/off control, full range line input capability and forced air cooling  
characteristics . 

1.

AC INPUT  

1.1 AC input requirements 

The input voltage, current, and frequency requirements for continuous operation are  
stated below. 

Table 1 AC Input Line Requirements 

Power factor correction (PF) >0.90 at full load. 

The power supply must meet inrush requirements for any rated AC voltage, during  
turn on at any phase of AC voltage, during a single cycle AC dropout condition, during  
repetitive ON/OFF cycling of AC, and over the specified temperature range (Top). The  
peak inrush current shall be less than the ratings of its critical components (including  
input fuse, bulk rectifiers, and surge limiting device). 

Parameter 

Vin (Full range) 

Vin (Full range,1200W) 

Vin Frequency 

Iin (750W) 

Iin (850W) 

Iin (1000W,1200W) 

Min 

90 

103 

47 

Nom 

100-240 

115-240 

60-50 

9.5-4.8 

11-5.5 

12-6 

Max 

264 

264 

63 

Unit 

VACrms 

VACrms 

Hz 

Arms 

Arms 

Arms 

02

 

STRIDER GOLD SERIES 

2. DC OUTPUT

2.1 DC voltage regulation 

 

 

 

 

1.Maximum continuous total DC output power should not exceed 750W. 
2.Maximum continuous combined load on +3.3VDC and +5VDC outputs shall not  
   exceed 150W. 
3.Maximum current for +12V outputs shall be 62A (744W). 
4.Maximum peak total DC output power should not exceed 850W. 
5.Peak power and current loading shall be supported for a minimum of 12 second. 
6.When +12V is load to 28A , -12V minimum load is 0.02A. 

2.2 Load ranges 

2.2.1: (ST75F-G Load Range) 

 

 

 

Parameter 

+3.3V 

+5V 

+12V 

-12V 

+5VSB 

Range 

+/-3

 

+/-3

 

+/-3

 

+/-10

 

+/-3

% 

Min 

+3.20 

+4.85 

+11.64 

-10.80 

+4.85 

Nom 

+3.30 

+5.00 

+12.00 

-12.00 

+5.00 

Max 

+3.40 

+5.15 

+12.36 

-13.20 

+5.15 

Unit 

Volts 

Volts 

Volts 

Volts 

Volts 

Parameter 

+3.3V 

+5V 

+12V 

-12V 

+5VSB 

Min 

0.3 

0.3 

0.1 

0.1 

Max 

22 

25 

62 

0.3 

3.5 

Unit 

Amps 

Amps 

Amps 

Amps 

Amps 

2.2.2: (ST85F-G Load Range) 

Parameter 

+3.3V 

+5V 

+12V 

-12V 

+5VSB 

Min 

0.3 

0.3 

0.1 

0.1 

Max 

22 

25 

70 

0.3 

3.5 

Unit 

Amps 

Amps 

Amps 

Amps 

Amps 

Содержание SST-ST1200-G

Страница 1: ...October 2010 NO G11212840 STRIDER GOLD ST1200 G ST1000 G ST85F G ST75F G The perfect balance of performance efficiency and quality ...

Страница 2: ...ut fuse bulk rectifiers and surge limiting device Parameter Vin Full range Vin Full range 1200W Vin Frequency Iin 750W Iin 850W Iin 1000W 1200W Min 90 103 47 Nom 100 240 115 240 60 50 9 5 4 8 11 5 5 12 6 Max 264 264 63 Unit VACrms VACrms Hz Arms Arms Arms 02 STRIDER GOLD SERIES 2 DC OUTPUT 2 1 DC voltage regulation 1 Maximum continuous total DC output power should not exceed 750W 2 Maximum continu...

Страница 3: ...hall not exceed 150W 3 Maximum current for 12V outputs shall be 100A 1200W 4 Maximum peak total DC output power should not exceed 1300W 5 Peak power and current loading shall be supported for a minimum of 12 second 6 When 12V is load to 28A 12V minimum load is 0 02A 2 2 4 ST1200 G Load Range Parameter 3 3V 5V 12V 12V 5VSB Min 0 3 0 3 0 1 0 0 1 Max 25 25 100 0 3 3 5 Unit Amps Amps Amps Amps Amps 04...

Страница 4: ...t Volts Volts Volts The power supply will be shutdown and latch off when output power within 105 150 of rated DC output Note Assurance machine can work at low voltage full load won t damage machine 3 2 Over power protection The power supply will be shutdown and latch off when output power within 105 150 of rated DC output Note Assurance machine can work at low voltage full load won t damage machin...

Страница 5: ...UIREMENTS The power supply designed to meet UL 1950 If applicable to sales in Japan or Europe the power supply shall meet the requirements of EN 61000 3 2 class D and the guidelines for the suppression of harmonics in appliances and general use equipment class D for harmonic line current content at full rated power 6 1 Underwriters Laboratory UL recognition The demonstrated MTBF shall be 100 000 h...

Страница 6: ...ck Black ATX 12V 4PIN 4 4PIN EPS 12V in split mode Black Black Signal GND GND Pin 1 2 Pin 3 4 Signal 12V 12V Yellow Yellow 9 2 Connectors 10 STRIDER GOLD SERIES SATA connector Orange Black Red Black Yellow Signal 3 3V COM 5V COM 12V Pin 5 4 3 2 1 8PIN PCI Express connector Yellow Yellow Yellow Black sense1 Signal 12V 12V 12V COM Pin 1 2 3 4 Pin 5 6 7 8 Signal COM COM COM COM Black Black Black Blac...

Отзывы: