03
2.2.2:(1200 Watts Load Range)
1.Maximum c.ontinuous combined load on +3.3V and +5V outputs shall not exceed 120W.
2.Maximum continuous total DC output power should not exceed 1200W.
3.Peak DC output power should not exceed 1300W for 12 second.
Parameter
+3.3V
+5V
+12V
-12V
+5VSB
Nom.
-
-
-
-
-
Min(optional)
0
0
0.15
0
0
Max
25
22
100
0.3
3
Peak
-
-
-
-
-
Unit
Amps
Amps
Amps
Amps
Amps
2.3.1 Ripple regulation
2.3.2 Definition
2.3.3 Ripple voltage test circuit
2.3 Output Ripple
The ripple voltage of the outputs shall be measured at the pins of the output connector when
terminated in the load impedance specified in figure 1. Ripple and noise are measured at the
connectors with a 0.1uF ceramic capacitor and a 10uF electrolytic capacitor to simulate system
loading. Ripple shall be measured under any condition of line voltage, output load, line frequency,
operation temperature.
Parameter
+3.3V
+5V
+12V
-12V
+5VSB
Unit
mVp-p
mVp-p
mVp-p
mVp-p
mVp-p
Ripple&Noise
50
50
120
120
50