02
2.3 Input power factor correction (Active PFC)
The power factor at 50% load shall be
≧
0.9 at 230V input voltage.
2.4 Input current harmonics
When the power supply is operated in 90-264 VAC of Sec. 2.1, the input harmonic current drawn on the power
line shall not exceed the limits set by IEC61000-3-2 Class A and GB17625.1 standards. The power supply shall
incorporate universal power input with active power factor correction.
2.5 Dropout
An AC line dropout of 17mS or less shall not cause any tripping of control signals or protection circuits. If the
AC dropout lasts longer than 17mS, the power supply should recover and meet all turn on requirements. The
power supply shall meet the regulation requirement over all rated AC voltages, frequencies, and output loading
conditions. Any dropout of the AC line shall not cause damage to the power supply. An AC line dropout is
defined as a drop in AC line to 0 VAC at any phase of the AC line for any length of time.
3.1 Output current / loading
3.2 DC voltage regulation, ripple and noise
The following table defines power and current rating. The power supply shall meet both static and dynamic
voltage regulation requirements for minimum load condition.
The power supply output voltages must stay within the following voltage limits when operating at steady state
and dynamic loading conditions. All outputs are measured with reference to the return remote sense (Returns)
signal. The +5V, +3.3V, +12V, -12V and +5VSB outputs are measure at the power supply connectors references
to Returns. The +5V and +3.3V is measured at its remote sense signal (+5VS, +3.3VS) located at the signal
connector.
Table 2– Output Loads Range 1
Note 1: Maximum continuous total DC output power should not exceed 600W.
3. DC output specification
Output Voltage
Max. Load
Min. Load
Max. Combined
Total Output
+5V
25A
1A
170W
600W
+3.3V
25A
1A
+12V
49A
1A
-
-12V
0.8A
0A
-
+5VSB
3.5A
0.1A
17.5W
Table 3 – Regulation, ripple and noise
Output Voltage
Load Reg.
Line Reg.
Ripple & Noise
+5V
+/-5
﹪
+/-1
﹪
50mV
+3.3V
+/-5
﹪
+/-1
﹪
50mV
+12V
+/-5
﹪
+/-1
﹪
120mV
-12V
+/-5
﹪
+/-1
﹪
120mV
+5VSB
+/-5
﹪
+/-1
﹪
50mV