background image

ıĹ

The following subsections define recommended environmental specifications and 
test parameters. Based on the typical conditions to which an ATX12V power supply 
may be subjected during operation or shipment.

Operating           0°C to +50°C (derating from 100 % to 80 % from 40 °C to 50 °C).
Non-operating  -20°C to +70°C

2.4.4. Short-circuit Protection

The power supply will shut down and latch off for shorting the +12V, +5V, +3.3V, 
and -12V rails to return or any other rails. Shorts between main output rails and 
+5Vsb will not cause any damage to power supply. +5Vsb can be capable of 
being shorted indefinitely, but when the short is removed, the power supply will 
recover automatically or by cycling PS_ON. The power supply can be capable of 
withstanding a continuous short circuit to the output without damage or overstress 
to the unit under the input conditions specified in section 2.1.

2.4.5. Over Power Protection

Fold back at 110%~150% over peak load

2.4.6. OVER TEMPERATURE PROTECTION

Protection temperature is 50

 to 70

 at 115V and full load

2.4.7. No-load Operation

No damage or hazardous condition will occur with all the DC output connectors 
disconnected from the load. The power supply may latch into the shutdown state.

2.4.8. Isolation (High Voltage Withstand)

1800Vac for 1 minute.

3.1. Temperature

3. Environmental

Содержание DA1000R Gold

Страница 1: ...s Gold 1000W 1200W PCIe 5 0 fully modular ATX PSU 100 modular cables Cybenetics Gold Certified All Japanese electrolytic capacitors 24 7 continuous power output with 50 C operating temperature Support...

Страница 2: ...The inrush current is less than 130A under the conditions of 230Vrms input and 25 C ambient cold start The inrush current is limited to the extent that no damage will be done to the power supply unde...

Страница 3: ...on 2 2 3 DC Output Efficiency Eup requirements DC Output Efficiency Table 3 DC Output Load Distrib10ution 1200W 1000W The power supply efficiency is 87 0 minimum measured at 20 efficiency is 90 0 mini...

Страница 4: ...random signals over a frequency band of 10Hz to 20MHz Measurements should be made with an oscilloscope with 20MHz bandwidth adding a 10uF electrolytic capacitor and a 0 1uF ceramic capacitor across o...

Страница 5: ...ltage limits 5 7 5 5 5 5 Capacitive Load 6600uF 3300uF 3300uF 470uF 470uF Table 9 DC Output Transient Response 2 3 Timing Housekeeping control 2 2 6 DC Output Voltage Hold up Time Step load changes up...

Страница 6: ...ed to TTL low the power supply should turn on the four main DC output rails 12 VDC 5 VDC 3 3 VDC and 12 VDC When PS_ON is pulled to TTL high or open circuited the DC output rails should not deliver cu...

Страница 7: ...ing its minimum in regulation level and 3 3V reaching its minimum in regulation level is 20 msec 2 3 7 Overshoot at Turn on Turn off The output voltage overshoot upon the application or removal of the...

Страница 8: ...supply can provide latch mode over voltage protection as defined in Table 12 2 4 2 Under Voltage Protection The power supply can provide latch mode Under voltage protection as defined in Table 13 2 4...

Страница 9: ...capable of being shorted indefinitely but when the short is removed the power supply will recover automatically or by cycling PS_ON The power supply can be capable of withstanding a continuous short c...

Страница 10: ...igh reliability All electronic components are designed with conservative derating for use in commercial and industrial environments 4 2 Mean Time between Failures MTBF 100K hours minimum at full load...

Страница 11: ...r berlastung des Netzanschlusses DE Die maximale Stromst rke eines einzelnen 8 poligen PCIe Kabels und Anschlusses betr gt 12 5 A was 150 W 12 V x 12 5 A entspricht Daher deckt die SilverStone Garanti...

Страница 12: ...superano l assorbimento totale di 375 W 300 W da doppi connettori PCIe a 8 pin 75 W dalla scheda madre PCIe La corrente massima del connettore periferico molex o SATA 5 A corrispondente a 60 W 12 V x...

Страница 13: ...x 2 12V SilverStone 3 H SLQ 9 3 H SLQ 3 H SLQ 3 H 3 H SLQ 3 H SLQ 3 H SLQ PROH 6 7 9 9 SLQ 9 9 9 CN TW 3 H SLQ 9 3 H SLQ 3 H SLQ 3 H 3 H SLQ 3 H SLQ 3 H SLQ PROH 6 7 9 9 SLQ 9 9 9 TH PCIe 8 12 5 150...

Страница 14: ...PP PP PP PP PP PP Openings that do not exceed 1mm in width regardless of length Openings that do not exceed 5mm in any dimension 60 52 6 KWWS ZZZ VLOYHUVWRQHWHN FRP GRZQORDGV 368 56 SGI...

Страница 15: ...accept any interference received including interference that may cause undesired operation Please refer to SilverStone website for latest specifications updates The equipment a Class Switching Power S...

Страница 16: ...NO G11246160...

Отзывы: