ELECTRICAL CONNECTION
11 ELECTRICAL CONNECTION
To connect the device to the electrical network, hire an
electrician who knows the local regulations of the local elec-
trical supply companies and carefully observes them.
The contact protection of operationally isolated parts must be
ensured after installation.
You will find on the nameplate whether the required connec
-
tion data correspond to those of the network
The device must be able to be disconnected by isolators all
poles of the mains. When switched off, there must be a con-
tact gap of 3 mm. LS-switches, fuses, RCD's and contac-
tors are considered as suitable separation devices
The installation must be protected by fuses. Electrical cables
must be perfectly covered by installation.
If the device is not equipped with an accessible plug, other
separation options must be considered for fixed installation
in accordance with the installation instructions.
The supply cable must be installed so that the hot parts of the
hob are not touched.
Attention !
This device is only designed for a power supply of 230 V ~ 50/60
Hz. Always connect the earth together. Note the connection
diagram. The connection box is located on the underside of the
device. To open the case, use a screwdriver and slide it into the
slots provided.
Network
Connection
Diameter
Electric
wire
Fuse
230V~
50/60Hz
1 Phase
+ N
3 x 2.5
mm²
H 05
VV - F
25 A *
H 05
RR - F
400V~
50/60Hz
2 Phasen
+ N
4 x 1.5
mm²
H 05
VV - F
16 A *
H 05
RR - F
(*) according to EN 60 335-2-6 standard
Connection of the hob:
For the various connection options, use the brass bridge terminals
located in the housing.
Monophases 230V ~ 1P + N