SEMK 105 A1
Malfunction Cause
Remedy
The ice cubes
produced are
too small .
Poor heat dissipation .
Set up the appliance so that it has a free
space of around 20 cm on all sides .
The water temperature is too
high .
Make sure that the water used is between
8 and 25°C .
The ambient temperature is
too high .
Make sure that the ambient temperature
is between 10 and 32°C .
Appendix
Technical data
Input voltage
220–240 V ∼ (alternating current), 50 Hz
Nominal current
0 .8 A
Rated power
105 W
Production volume
11 – 12 kg /24 hours
Capacity of the water tank
1,8 L
Capacity of the ice basket
800 g
Refrigerant
R600a, 29g
Climate class
SN, N, ST, T
Heat insulating material
Cyclopentane
All of the parts of this appliance that come
into contact with food are food-safe .