
9
GB
Q
Removing part of the weight
from the kitchen scale
Place the weighing bowl
1
on the weighing
platform
6
.
Press the On / Off / Zero button
5
to switch
on the kitchen scale
2
.
Wait until the LC display
4
stops and stabilizes
on 0 g
17
, 0:0.0 lb:oz
20
or 0 ml
18
or
0.0 fl’oz
19
, which will be the mode the kitchen
scale was in when it was last switched off.
Press the mode button
3
to set the weighing
mode
23
(preset to g or lb:oz).
Place the substance to be weighed into the
weighing bowl
1
to start the weighing process.
The LC display
4
shows the weight of the first
substance placed in the weighing bowl.
Press the On / Off / Zero button
5
to reset the
LC display
4
to zero.
Now remove the desired amount of substance
from weighing bowl
1
. The LC display
4
shows the weight of the substance removed
from the weighing bowl as a negative value.
Q
Automatic or manual switch-off
The kitchen scale switches itself off automatically
if it has not been used for 2 minutes.
Press the On / Off / Zero button
5
for longer
than 3 seconds to switch off the kitchen scale.
Q
Volume units display mode
Place the kitchen scale on
a solid, flat surface.
Press the On / Off / Zero
button
5
to switch on the
kitchen scale
2
.
Wait until the LC display
4
stops and stabilizes on
0 g
17
, 0:0.0 lb:oz
20
or
0 ml
18
or 0.0 fl’oz
19
,
which will be the mode the
kitchen scale was in when
it was last switched off.
Press the mode button
3
until milk
22
or water
21
appears as the volume
mode with the units as ml
or fl’oz.
Place a container for liquid
or the weighing bowl
1
on the weighing platform
6
.
Press the On / Off / Zero button
5
to set the
LC display
4
to zero (0 ml or 0.0 fl’oz). Pour
milk or water (as selected previously) into the
container.
The LC display
4
now automatically shows
the volume of liquid poured into the container,
either in ml or in fl’oz, depending on the setting.
Then press the mode button
3
to set the kitchen
scale to weighing mode again and read off the
equivalent weight of the liquid.
Q
Troubleshooting
Error
Cause
Solution
The LCD readout
4
indicates “Err” and
does not change.
The maximum capacity of
the kitchen scale
2
of
5 kg / 11 lb has been
exceeded.
Remove the food from the kitchen scale
2
.
Switch the kitchen scale
2
off and then back
on again.
Reduce the amount of food and weigh it in
several steps.
The LCD readout
4
indicates “Lo”.
The battery is empty.
Replace the battery as described in the
“Replacing the battery” chapter.
Getting started / Troubleshooting
Getting started
104631_silv_Digitale Kuechenwaage_Content_PL_HU_SI_CZ_SK.indd 9
05.01.15 15:22