background image

 

 

 

OPERATION

 

Initial Start Up:

 

After satisfying the installation requirements, the unit is ready to start.  The unit will start when the power cord is connected to the 
required power source.  If the compressor does not start when the unit is initially plugged in, check to make sure that the 
temperature control is not in the 'off' position.  Allow the unit to run a minimum of two hours before loading it with product.  When 
loading the unit with product, take care not to block the air flow at the back of the cabinet as this would affect the performance of the 
cabinet. 
 

Temperature Control

 

The  Temperature  Control  is  located  on  the  back  of  the  cabinet  and  is  factory  set  to  maintain  an  average  cabinet  temperature  of 
approximately 0 Deg F.  To obtain colder temperatures, press and hold the set button until the set point value flashes.  Use the up or 
down arrow buttons to change the value and then press the set button again.  Allow the unit a minimum of one hour to resp ond to a 
control setting adjustment. 
 

Defrost:

 

Your Silver King unit is an automatic defrost unit.  No additional plumbing is required.  Automatic defrosting is accomplished by a 
defrost heater and timer.  Defrost water is collected in a pan located in the compressor compartment where it is evaporated into the 
room air.  It is important that the unit be level so the condensate can drain properly. 
 

MAINTENANCE

 

Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of 
the appliance. 
 

Cabinet Surfaces:

 

The cabinet interior is aluminum and the exterior is stainless steel.  These surfaces should be cleaned periodically with a solution of 
warm water and mild soap.  After cleaning the surfaces, they should be rinsed with clean water and wiped dry with a soft cloth.  
Stainless steel cleaners can be used on the exterior.  Should a surface become stained, do not attempt to clean with an abrasive 
cleaner or scouring pad.  Use a soft cleanser and rub with the grain of the metal to avoid scratching the surface.   Always rinse well 
and dry after cleaning.  Do not use chlorinated cleaners. 
 

Condenser 

Periodically, accumulated dust must be removed from the condenser. First, disconnect the unit from the power supply. To clear the 
dust, vacuum or brush the condenser at the bottom rear of the cabinet. This will need to be done regularly to maintain the 
compressor warranty! 

WARNING:  The condenser fins are very sharp, use caution when cleaning the condenser. 

 

Drawer Gasket

 

The Drawer Gasket will collect dirt and should be wiped clean with a warm, mild soapy water solution to extend its life and assure 
maximum cabinet performance and life. 
 
 

MODEL 

SERIAL NO. 

DATE INSTALLED 

Содержание SKF27A-ED 115V

Страница 1: ...cal Manual Replacement Parts List 1600 Xenium Lane North Minneapolis MN 55441 3787 Phone 763 923 2441 Freezer MODEL SKF27A ED 115V FORM NO 45071 REV D 07 2021 Specifications Subject to Change Without...

Страница 2: ...t altitudes higher than 2000 meters Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance Do not exceed the maximum load capacity of 75 pounds per drawer...

Страница 3: ...ll the stop levers out on the Cabinet Drawer Tracks and lift up and pull the Drawer out To reinstall the Drawer line up the Drawer Tracks on the cabinet and the Drawer push the Drawer into the cabinet...

Страница 4: ...re it is evaporated into the room air It is important that the unit be level so the condensate can drain properly MAINTENANCE Preventative maintenance is minimal although these few steps are very impo...

Страница 5: ...4...

Страница 6: ...5...

Страница 7: ...CONDENSER OPTIONAL 31221 CASTER KIT 2 10314 100 CASTER KIT 3 10314 63 17 KIT COMPRESSOR W ELECTRICALS 115V 60HZ 11700 2 18 KIT ELECTRICALS 115V RELAY OVERLOAD RUN CAPACITIOR 11701 2 19 GROMMET COMPRE...

Страница 8: ...7...

Страница 9: ...pare the multimeter s reading to Table 1 Analyze Results If the resistance and temperature are similar then the thermistor is working properly and does not need to be replaced If the resistance and te...

Страница 10: ...ollowing the 1 year labor warranty period or other incidental or consequential costs including product and or economic loss This Equipment warranty is in lieu of all other warranties express or implie...

Страница 11: ...ce include but are not limited to temperature control adjustments temperature indicator calibrations coil and filter cleaning or condensate drain cleaning A second service call for a related failure i...

Страница 12: ...LIMITED TO INDIRECT PUNITIVE DAMAGES LOSS OF USE LOSS OF PRODUCT DOWNTIME OR LOST PROFITS ARISING OUT OR RELATED TO OR CONNECTED IN ANY WAY WITH THE PRODUCT OR ITS USE Silver King 1600 Xenium Lane Pl...

Отзывы: