background image

 

 

 

 

TECHNICAL MANUAL 

SILVER KING FRONT BREATHING FREEZER 

MODEL SKF27A-ED

 

Thank  you  for  purchasing  Silver  King  food  service  equipment.    Our  goal  is  to  provide  our  customers  with  the  most  reliable 
equipment in the industry today.  Please read this manual and the accompanying warranty information before operating your 
new Silver King unit. 
 

INSPECT FOR DAMAGE AND UNCRATE

 

Upon delivery of your new Silver King unit, uncrate at once to examine and test for possible damage following the instructions 
printed on the exterior of the container.  Report any damages to the carrier responsible for transportation and promptly present 
a claim for any evidence of mishandling.  Save all packaging materials if a claim must be filed. 
 

PRECAUTIONS BEFORE USING THIS PRODUCT 

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, 
or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance 
by a person responsible for their safety. 

 

Use caution when cleaning the condenser, the fins are very sharp. 

 

For units with a dual hertz rating, no adjustments are required for normal operation. 

 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in 
order to avoid a hazard. 

 

This refrigeration unit is not intended to be used at altitudes higher than 2000 meters. 

 

Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance. 

 

Do not exceed the maximum load capacity of 75 pounds per drawer. 

 

Use caution when moving, installing, maintaining and using this refrigeration device to avoid either damaging 
the refrigerant tubing or increasing the risk of a leak. 

 

All component parts must be replaced with like components and all servicing must be done by factory 
authorized service personnel, so as to minimize the risk of possible ignition due to incorrect parts or improper 
service. 
 

If the unit has recently been transported on its side (or placed horizontally), then please let unit stand with the casters (or 
feet) on the ground for a minimum of 24 hours before plugging it in. 

FOR HYDROCARBON UNITS ONLY (R290)

 

 
Danger 

– Risk of fire or explosion.  Flammable refrigerant used.  To be repaired only by trained service personnel.  Do not puncture 

refrigeration tubing. 

 
Danger 

– Risk of fire or explosion.  Flammable refrigerant used.  Do not use mechanical devices to defrost refrigerator/freezer.  Do 

not puncture refrigeration tubing. 
 

Caution

 

– Risk of fire or explosion.  Flammable refrigerant used.  Consult repair manual/owner’s guide before attempting to service 

this product.  All safety precautions must be followed. 

 
Caution

 

– Risk of fire or explosion.  To be repaired only by trained service personnel.  Use only Silver King approved replacement 

parts.  Flammable refrigerant used. 
 

Caution

 

– Risk of fire or explosion.  Dispose of properly in accordance with federal or local regulations.  Flammable refrigerant used. 

 

Содержание SKF27A-ED 115V

Страница 1: ...cal Manual Replacement Parts List 1600 Xenium Lane North Minneapolis MN 55441 3787 Phone 763 923 2441 Freezer MODEL SKF27A ED 115V FORM NO 45071 REV D 07 2021 Specifications Subject to Change Without...

Страница 2: ...t altitudes higher than 2000 meters Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance Do not exceed the maximum load capacity of 75 pounds per drawer...

Страница 3: ...ll the stop levers out on the Cabinet Drawer Tracks and lift up and pull the Drawer out To reinstall the Drawer line up the Drawer Tracks on the cabinet and the Drawer push the Drawer into the cabinet...

Страница 4: ...re it is evaporated into the room air It is important that the unit be level so the condensate can drain properly MAINTENANCE Preventative maintenance is minimal although these few steps are very impo...

Страница 5: ...4...

Страница 6: ...5...

Страница 7: ...CONDENSER OPTIONAL 31221 CASTER KIT 2 10314 100 CASTER KIT 3 10314 63 17 KIT COMPRESSOR W ELECTRICALS 115V 60HZ 11700 2 18 KIT ELECTRICALS 115V RELAY OVERLOAD RUN CAPACITIOR 11701 2 19 GROMMET COMPRE...

Страница 8: ...7...

Страница 9: ...pare the multimeter s reading to Table 1 Analyze Results If the resistance and temperature are similar then the thermistor is working properly and does not need to be replaced If the resistance and te...

Страница 10: ...ollowing the 1 year labor warranty period or other incidental or consequential costs including product and or economic loss This Equipment warranty is in lieu of all other warranties express or implie...

Страница 11: ...ce include but are not limited to temperature control adjustments temperature indicator calibrations coil and filter cleaning or condensate drain cleaning A second service call for a related failure i...

Страница 12: ...LIMITED TO INDIRECT PUNITIVE DAMAGES LOSS OF USE LOSS OF PRODUCT DOWNTIME OR LOST PROFITS ARISING OUT OR RELATED TO OR CONNECTED IN ANY WAY WITH THE PRODUCT OR ITS USE Silver King 1600 Xenium Lane Pl...

Отзывы: