Cream Dispenser
Model SK-2
SK-2 Cream Dispenser
11
Master Display Messages
PROBLEM
PROBABLE CAUSE
SOLUTION
Compressor will not run
No Voltage at wall receptacle
Check circuit breaker or fuse
Service cord pulled out of wall receptacle
Call for service (888-375-2938).
Low voltage causing compressor to cycle on
overload
Contact power company and confirm that
voltage fluctuation does not exceed 10%
plus or minus from the nominal rating.
Power switch is in “Off” position
Turn switch on
Inoperative Control
Call for service (888-375-2938).
Compressor stuck
Call for service (888-375-2938).
Compressor windings open
Call for service (888-375-2938).
Compressor overload stuck open
Call for service (888-375-2938).
Relay lead loose
Call for service (888-375-2938).
Relay loose or inoperative
Call for service (888-375-2938).
Power cord disconnected from dispenser
Call for service (888-375-2938).
Faulty cabinet wiring
Call for service (888-375-2938).
Compressor runs but no refrigeration
System out of refrigerant
Call for service (888-375-2938).
Compressor not pumping
Call for service (888-375-2938).
Restricted filter drier
Call for service (888-375-2938).
Restricted capillary tube
Call for service (888-375-2938).
Moisture in system
Call for service (888-375-2938).
Compressor short cycles
Erratic Control Thermostat
Call for service (888-375-2938).
Low Voltage
Contact power company and confirm that
voltage fluctuation does not exceed 10%
plus or minus from the nominal rating.
Compressor draws excessive wattage
Call for service (888-375-2938).
Faulty relay
Call for service (888-375-2938).
Compressor runs too much or constantly
Temperature too low
Adjust temperature control
Erratic Control
Call service technician
Abnormally high room temperature
Reduce room temperature or relocate dis-
penser
Door or lid gaskets not sealing
Adjust or Call for service (888-375-2938).
System undercharged due to leaks
Call for service (888-375-2938).
System undercharged from factory
Call for service (888-375-2938).
System overcharged
Call for service (888-375-2938).
System not clean
Call for service (888-375-2938).
Restricted filter drier
Call for service (888-375-2938).
Restricted capillary tube
Call for service (888-375-2938).
Troubleshooting Steps