background image

 
                                                               

Innovative Solar Solutions | 2917 State Hwy 7, Bainbridge, N.Y. 13733 | Ph: 800.786.0329 | www.SiliconSolar.com 

 

 

 

 

*    Do not short circuit the lead wires, fail to do so may cause sparking or explosion 
*    Reduce the length of connecting wire whenever possible, in order to reduce power loss. 

 

Working status can be monitor via the LCD display.    Switch “

 is available to show data 

shifting between 

 
 
 
 
 
 
                     

 
 

 

Switch 

  is available to turn the load ON/OFF. When the LCD display shows sign of   

 

Connection to load is turned ON.    But if the Over discharge protection is activated,   
connection will of OFF, even it shows the sign   

 

The charge regulator provides following protections for the whole system 

1.

 

Over-discharge protection

: When activated, “Low Voltage” indicator will go on, the charge 

regulator will shut off power output to prevent damage to the battery. In such case, Please 
stop using any application. 

2.

 

Over-charge protection:

 When activated, “High Voltage” indicator will go on, the charge 

regulator will shut off power input from solar panel to battery.    Please disconnect solar 
panel from the charge regulator.   

 

Trouble Shooting: 

 

Problem 

Possible Causes 

Possible Solutions 

LCD display shows no 
charging when Solar 
module is connected 

1.

 

Reverse polarity 

2.

 

Loose connection 

3.

 

Not enough sun light 

1.

 

Correct connection with correct polarity 

2.

 

Make sure connection is tight 

3.

 

Position solar module in full sunlight 

Can not use Load 

1.

 

Load switch is OFF 

2.

 

No battery connected or battery 
connection loose, or reverse 
polarity 

3.

 

Load polarity connection is reversed 

4.

 

Over discharge protection activated 

5.

 

Short circuit or over load protection 
activated 

1.

 

Press 

  until LCD shows 

 

2.

 

Connect battery to charge regulator, 
and make sure connection is tight & 
with correct polarity 

3.

 

Correct reverse polarity 

4.

 

Disconnect load, recharge battery fully 

5.

 

Check if connection is short circuiting, and 
make sure the load current is not 
exceeding 30A.. When all are O.K., Press 

     

 

 

 

 

 

 

 

 

 

Battery voltage

 

Discharge current from battery to load

  Charging current from solar panel to battery 

Отзывы: