![Silicon Solar AQUAJET-CUSTOM-KIT-24V-V2 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/silicon-solar/aquajet-custom-kit-24v-v2/aquajet-custom-kit-24v-v2_user-manual_1272079003.webp)
Innovative Solar Solutions | 2917 State Hwy 7, Bainbridge, N.Y. 13733 | Ph: 800.786.0329 | www.SiliconSolar.com
If the pump starts losing power or stops working after operating for a certain time, please clean up the sediment
inside the pump or the debris on the filter cribs.
The pump can be opened by unscrewing the four screws on the four corners of the filter housing bottom.
To clean the pump, disassemble the pump according to the above figure and then clean all the parts with water.
Be careful, never drop down the ceramic axis while cleaning the impeller, it breaks easily.
6. TROUBLE SHOOTING
Pump does not operate, please check the following possible reasons:
1) No connection to the power supply.
2) Impeller is blocked—to clean the pump as described in “
CLEANING AND MAINTENANCE
”.
3) To be sure the pump is fully submerged in water.
*Pump does operate but there is no water running through the tubes: Clear the tube and the filter to
make sure the tube is through completely.
7.
TECHNICAL DATA AND PUMP CURVE
Peak Power of
50W
Operating
18V
Maximum pump
2.1m
Maximum flow
2480L/H
Cable length
5 M