7. Download the project to the target by clicking the Download Code button in the toolbar.
Note:
To enable automatic downloading if the program build is successful, select
Enable automatic connect/download
after build
in the
Project
Target Build Configuration
dialog. If errors occur during the build process, the IDE will
not attempt the download.
8. Connect a load to the V
OUT
terminals (J3 and J4) as shown in Figure 2 on page 3.
For initial testing, a 2
,
15 W resistor is recommended. For higher output currents, an electronic load simulator can be used.
9. Run the converter firmware by pressing the “Go” button in the IDE toolbar. The converter will start up and
provide 3.3 V at V
OUT
.
10.Save the project when finished with the debug session to preserve the current target build configuration, editor
settings, and location of all open debug views. To save the project, select
Project
Save Project
from the
menu.