5.2. Measuring Power
This section discusses the hardware setup and code required to reproduce the power specifications reported by
the SiM3L1xx data sheet.
5.2.1. Hardware Setup
To measure the power on the SiM3L1xx MCU Card with a fixed 3.3 V VBAT:
1. Connect a USB Debug Adapter to the 10-pin CoreSight connector (J14).
2. Remove the three shorting blocks from J7.
3. Remove the JP2
Imeasure
shorting block and put a multimeter across (positive side on the bottom pin).
4. Move the
VBAT Sel
switch (SW2) to the 3.3 V_VREG position.
5. Move the
VIO Sel
(SW8) and
VIORF Sel
(SW9) switches to the bottom VBAT position.
6. Connect the 9 V power adapter to POWER (J6).
7. Download the code to the board.
8. Remove the debug adapter connection.
9. Measure the power of the device.
Figure 5. SiM3L1xx MCU Card Power Measurement Configuration—Fixed VBAT