Power-On Communication & Presets
Initial State
When the power is first applied to the camera the camera will load its default (Preset #0) settings and will be
generating live video and a serial status message. Preset #1 can be overwritten thru programming commands. Once
Preset#1 is overwritten it will be the new power-on default setting.
If the Frame Grabber supports a serial terminal mode the following menu will appear:
100: Booted
108: CameraLink SI3300 3.12.08
120:C2010610 Sensor tag
190:66633035 Configuration code
's' - status
Returns the firmware version, clock configuration word, Sensor Tag, and FPGA Configuration code. Camera output
example:
108: CameraLink SI3300 3.06.08
110:306882 Clock
120:C2010610 Sensor tag
190:66633035 Configuration code
Default Settings
When first turned on, the SI-3300 will be in the default mode, which will be 10 fps Full Frame Readout at 40MHz
master clock. See serial programming section for details on changing formats.
Full Resolution, Rolling Shutter, Single-slope, 40MHz
Resolution = 2048 x 1536
Clock =
40MHz
Integration = 1561 Rows
Global Gain = 2.0
Frame Rate = 11 FPS