Silicon Graphics SG1 Скачать руководство пользователя страница 3

 
     3 Introduction      
 

      3-1 Battery operation 
  
      

Front view

 

      A. ON/OFF switch:

 Leave in the OFF position during   installation. 

      B . Over heat protection:

 LED sparkles when product temperature   

      gets high, it would shut down automatically while temperature arrives   
      55

°C±5°C. 

      C.Overload protection:

 Orange LED lights when inverter/charger shut   

      down due to overloading. Inverter would re-start one time, if failed,   
      inverter would shut down. Please turn inverter OFF, reduce load and  
      turn inverter ON to reset. 

      D. AC socket: 

German 

      E. USB port : 

Max. Current 2A

 

 

      F. Light switch : 

the light in front panel can supply lighting if needed 

       

     Side view:

 

      A . Ventilation window:

 Do not obstruct, allow at least one inch for   

      airflow. 
      

B. Fuse:

40A/32V.If fuse damaged , please change it according to the   

       specification . 
       

C. Solar port:

 MC4 Standard 

       D. Battery terminals:

 Connect to 12V battery or other 12Vpower  

       

source. "+“ is positive, "-" is negative. 

       Reverse polarity connection will blow internal fuse and may damage  
       inverter permanently.

'Damage caused by reversed polarity is not   

       

covered by the warranty.‘ 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

4

 

WARNING!!

 

Operation of the inverter without a 
proper ground connection may result 
in an electrical safety hazard.

 

 

     

3-2 Panel operation 

  
      

Front view

 

      A. ON/OFF switch:

 Leave in the OFF position during   installation. 

      B . Over heat protection:

 LED sparkles when product temperature  

      gets high, it would shut down automatically while temperature arrives  
      55

°C±5°C. 

      C.Overload protection:

 Orange LED lights when inverter/charger shut  

      down due to overloading. Inverter would re-start one time, if failed,  
      inverter would shut down. Please turn inverter OFF, reduce load and  
      turn inverter ON to reset. 

      D. AC socket: 

German 

      E. USB port : 

Max. Current 2A

 

 

      F. Light switch : 

the light in front panel can supply lighting if needed 

       

     Side view:

 

      A . Ventilation window:

 Do not obstruct, allow at least one inch for   

      airflow. 
      

B. Fuse:

40A/32V.If fuse damaged , please change it according to the   

       specification . 
      

C. Solar port:

 MC4 Standard 

      D. Battery terminals:

 Connect to 12V battery or other 12Vpower  

      source. "+"  
       is positive, "-" is negative. 
       Reverse polarity connection will blow internal fuse and may damage  
       inverter permanently.

'Damage caused by reversed polarity is not  

       covered   
        

by the warranty.‘ 

 

      
      

3-3 Status LED 

  

 
 
 
 
 
 
 
 
 

 

5

 

Содержание SG1

Страница 1: ... Status LED 5 4 Electrical Performance 6 7 4 1 Specification SG1 6 4 2 Specification Solar Charger Controller 7 5 Introduction 8 10 5 1 Solar Generator SG1 8 5 2 Front view and side view 8 9 5 3 LED Indicator Display function 10 6 Installation and Warning 11 13 6 1 Installation 11 12 6 2 Follow these guideline 12 6 3 Inverter Operation 13 6 4 Battery Installation and Replacement 13 7 Symbols Expla...

Страница 2: ...onal metal items such as rings bracelets necklaces and watches when operating with a lead acid batteries Doing so may cause short circuit and very high temperature which can melt metal items and even burn you 2 2 Features Modified sine wave output Output frequency50 Hz Input output fully reinforce isolated design High efficiency 75 Driving highly reactive capacitive loads at start moment Color ind...

Страница 3: ...rsed polarity is not covered by the warranty 4 WARNING Operation of the inverter without a proper ground connection may result in an electrical safety hazard 3 2 Panel operation Front view A ON OFF switch Leave in the OFF position during installation B Over heat protection LED sparkles when product temperature gets high it would shut down automatically while temperature arrives 55 C 5 C C Overload...

Страница 4: ...d short circuit protection 1 25 rated load current 60sec 1 5 rated loads current 5sec over load protection action 3 Rated load current short circuit protection action Self consumption current 6mA Charge circuit voltage drop 0 26V Load circuit voltage drop 0 15V Over voltage protection 17V 12V 34V 24V Work temperature Industry stage 35 C to 55 C Commercial stage 5 C to 50 C Boost charge voltage 14 ...

Страница 5: ... design bulk absorption float Wide volt range operation 90 135V 180 265V Durable and corrosion resistant construction 9 Transformer isolated for safety Bypass function Emergency backup light LED function 20A PWM Solar charger controller function option Max 100Ah battery space USB port 5V 2A 5 2 Front view and side view 8 10 11 DO NOT use this 2nd DC terminal alone Please connect the main battery c...

Страница 6: ...e recommended wire lengths and sizes 8AWG Do not mount the Inverter where it will be exposed to the gases produced by the battery These gases are very corrosive and prolonged exposure will damage the Inverter WARNING Shock Hazard Before proceeding further carefully check that the Inverter is NOT connected to any batteries and that all wiring is disconnected from any electrical sources Do not conne...

Страница 7: ... Operation To operate the power inverter use the ON OFF switch on the Front panel to turn the power on Then the power inverter is ready to deliver AC power to your loads If there is several loads use turn them on separately after the inverter is ON in order to prevent OVP resulted from the surge power 6 3 1 Set the power switch to ON position Then the inverter will make self diagnosis and the LED ...

Страница 8: ...d electronic equipment and batteries should be recycled at a facility capable of handing these items and their waste byproducts Contact your local authority for details in locating a recycle facility nearest to you Proper recycling and waste disposal will help conserve resources whilst preventing detrimental effects on your health and the environment 7 2 Recommend Accessories 7 2 1 PV Solar panel ...

Отзывы: