Router Board Installation

For the complete router board replacement procedure, refer to

SGI Origin 3000 Hardware Replacement

Procedures

, 108-0249-001––available online at

http://servinfo.corp.sgi.com/sgi3000/108-0249-001/

.

Caution:

To prevent component damage, observe all ESD precautions when you complete these steps.

1.

Gently remove the router board from the packaging. Place one hand on the router-board heatsink
and the other on the edges of the router board.

2.

Carefully position the router board in the brick and slide it toward the brick rear until the 8 DNET
connectors pass through the cutouts. Refer to Figure 3.

Caution:

To prevent router-board damage, handle the router board with extreme care and avoid
contact with the board’s electrical modifications.

3.

Install the 16 guide pins that secure the DNET connectors to the brick rear.

4.

Insert the baffle extension in the air-deflector slots; then, secure it with a T20 Torx screw.

5.

Connect the power board to the router board, secure the power board to the enclosure with 4 T20
screws, connect the three wire harnesses to the power board, and install the power-board VRM.

6.

Install the brick’s top cover and secure it with 4 T20 Torx screws.

7.

Install the brick in the rack and test it.

Figure 3 Installing the Router Board and Power Board

PCA router board

Air deflector

Baffle extension

Torx screw

Guide posts

Router board 
connector

VRM