Cleaning Compression Connectors
007-4209-003
119
Cleaning Compression Connectors
A compression connector should never need to be cleaned if you keep the protective
cover on whenever the module or board is not in the chassis. However, if the connector
becomes dirty, follow these steps for removing pollutants:
Note:
Some pollutants can irreversibly damage (corrode or chemically alter) the pad
surfaces. Although cleaning may remove the pollutant, it does not repair damage
incurred by this contact.
1.
Obtain a can of dry compressed air or inert gas. The Envi-Ro-Tech 1671 Duster
product manufactured by Tech Spray, L.P. (tel806 372 8523) works
extremely well for this application.
Caution:
Do not use a cleaning product that contains any of the following
ingredients: halogenated hydrocarbons, aromatic hydrocarbons, ethers, sulfur,
ketones, or solvents of any kind. These substances cause irreparable damage to the
connector’s surface.
2. Prepare the can for use, as instructed on the can. For example, if a tube is provided,
attach it to the can’s dispensing mechanism.
!