100
Chapter 4: Technical Reference
General Procedure to Change a Jumper Setting
The short general procedure for changing a configuration setting is the same for most of
the jumper functions, and is described in the following steps.
1.
Read and observe the safety and ESD precautions at the beginning of Chapter 1.
2. Turn off all connected peripherals, turn off system power, and disconnect all AC
power cords.
3. Remove the access cover. You do not need to remove the baseboard from the chassis,
and you probably do not need to remove any add-in boards.
4. Locate the configuration jumpers at the edge of the baseboard toward the front of
the system, near the narrow SCSI connector.
5. Move jumper to pins specified for the desired setting.
6. Reinstall the access cover using the original screws, connect the power cords, and
turn on the system for the change to take effect.
7. You may need to repeat these steps to move the jumper back to its original setting,
depending on the jumper function.
Table 4-19
Baseboard Jumper Summary
Function
Pins (default in bold)
What it does at system reset
CMOS clear
1-2, BMC Control
Preserves the contents of NVRAM.
2-3, Force Erase
Replaces the contents of NVRAM with the
manufacturing default settings.
Password clear
5-6, Protect
Maintains the current system password.
6-7, Erase
Clears the password.
Recovery Boot
9-10, Normal
System attempts to boot using the BIOS stored in
flash memory.
10-11, Recovery
BIOS attempts a recovery boot, loading BIOS code
from a diskette into the flash device. This is
typically used when the BIOS code has been
corrupted.
Содержание 1400
Страница 1: ...SGI 1400 Server Family Maintenance and Upgrades Guide Document Number 007 3948 001 ...
Страница 12: ......
Страница 14: ......
Страница 30: ...16 Chapter 1 Working Inside the System Figure 1 7 Removing EMI Shields ...
Страница 70: ......
Страница 78: ......
Страница 130: ......
Страница 150: ......
Страница 152: ......
Страница 156: ......
Страница 162: ......