![Silex technology GPF164092 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/silex-technology/gpf164092/gpf164092_owners-manual_1271355006.webp)
The National Electric Code requires that a ground fault circuit interrupter (GFCI) be used in the branch circuit supplying
fountain pumps and other pond equipment. See your electrical supplies dealer for this device.
To reduce the risk of electrical shock, use only on portable self-contained fountains no larger than 5 feet in any dimension.
Do not use with water above 35
℃
(95°F).
The pump is to be supplied through a residual current device(RCD) with a rated residual operating current not exceeding
30mA
CAUTION
Always disconnect from electrical outlet before handling the pump.
Don’t operate without water.
Do not lift the pump by the power cord.
For liquids having a temperature not exceeding 35
℃
(95°F).
Operate in freshwater only.
Operate pump completely submerged for proper cooling.
Not for swimming pool.
This pump has been evaluated for use with water only
PERFORMANCE
A clogged or dirty intake screen will greatly reduce performance.
If the pump is used on a dirty surface, raise it slightly to reduce the amount of debris contacting the intake. If slower flow is
desired, adjust the flow control lever on the side of the pump or restrict the discharge flow.
Do not let the pump run when not submerged in water. Doing so may damage the pump. Always submerge the pump in the
water before plugging in the electrical outlet. It is common for air to be in the pump and tube when first plugged in. Continue
to unplug the electrical cord and then plug it back in until water begins to flow.
This pump is only to be used in an outlet with a ground fault circuit interrupter (GFCI) or residual current device (RCD) with
a rated residual operating current not exceeding 30 mA.
NOTE: Ensure that the electrical cord loops below the electrical outlet to form a “Drip Loop” This will prevent water from
running down the cord into the electrical outlet.
MAINTENANCE
NOTE:
Always disconnect from electrical outlet before handling the pump
.
To clean the pump, remove the back cover and the impeller. Use a small brush or stream of water to
remove any debris
IF THE PUMP FAILS TO OPERATE, CHECK THE FOLLOWING:
Check the circuit breaker and try another outlet to ensure the pump is getting electrical power.
Check the pump discharge and tubing for kinks and obstructions. Algae build up can be flushed out with a garden hose.
Check the inlet to ensure it is not clogged with debris.
Remove the pump inlet to access the impeller area. Turn the rotor to ensure it is not broken or jammed.
Monthly maintenance will add to your pump’s life.
Distributor-
Silex GmbH
-
Weinstrasse 22 – D63628 Bad Soden-Salmünster - Tel. 06056-91200 – Fax 06056-912010
Email: [email protected] – www.silex.de