Distributed Power Module

MODEL 5495

Installation and
Operations Manual

Document 151161
                            Rev P

151161:

P

    ECN 17-0298

Содержание 5495

Страница 1: ...Distributed Power Module MODEL 5495 Installation and Operations Manual Document 151161 Rev P 151161 P ECN 17 0298 ...

Страница 2: ......

Страница 3: ...otification Circuits 10 Class A Supervised Input Circuits 10 4 5 2 Class B Supervised Wiring 11 Class B Output Notification Circuits 11 Class B Supervised Input Circuits 12 4 6 Ground Fault Detection Enable Disable Jumper 12 4 7 Battery Connection 12 4 8 DIP Switch Settings 13 4 8 1 Selecting the Standard Input Output Configurations 13 4 8 1 1 Input Output Configurations That Select ANSI Temporal ...

Страница 4: ... 3 Door Holder Application 21 Section 6 Troubleshooting 21 6 1 LEDs 21 6 2 Trouble Conditions 22 6 3 Earth Fault Resistance 23 6 4 Removing and Replacing the Control Panel 23 6 4 1 Removing the Control Panel 23 6 4 2 Replacing the Control Panel 24 Appendix A UL Listed Notification Appliances 26 A 1 Notification Appliances 26 Fire Product Warranty and Return Policy Manufacturer Warranties and Limit...

Страница 5: ...the battery standby power When the auxiliary power is configured to switch off there is a 30 second delay before the auxiliary power is turned off after the AC power fails see Section 4 8 4 for details Form C Trouble Relay The 5495 includes a general trouble relay that will de energize for any trouble situation see Section 4 4 1 for details Earth Fault Detection The 5495 monitors for earth faults ...

Страница 6: ...AC 60 Hz 2 A 2 Earth Ground 3 AC white neutral TB2 1 Auxiliary Power 27 4 VDC 3 0 amps 2 Auxiliary Power 3 Notification 4 Output 27 4 VDC 3 0 amps 4 Notification 4 Output Although each output 5 Notification 3 Output 27 4 VDC 3 0 amps is rated for 3 amps the 6 Notification 3 Output total current draw from 7 Notification 2 Output 27 4 VDC 3 0 amps the 4 outputs and the 8 Notification 2 Output auxili...

Страница 7: ...en with forward polarity to activate the outputs the main control panel will not be able to sense trouble conditions through its notification appliance circuit connected to the 5495 input circuits Use the 5495 trouble relay when it is necessary to monitor trouble conditions and active alarm conditions at the same time Section 6 explains the significance of each trouble condition in more detail 3 3...

Страница 8: ...Input 2 Outputs 3 and 4 Class B circuits 7 Input 1 Outputs 1 2 Class A circuit pair Input 2 Outputs 3 4 Class A circuit pair 8 Input 1 Outputs 1 2 Class A circuit pair Input 2 Outputs 3 and 4 Class B circuits 9 Input 1 Strobe Control All outputs Class A or Class B Input 2 Audio Control Faraday Sync Output 10 Input 1 Strobe Control All outputs Class A or Class B Input 2 Audio Control Gentex Sync Ou...

Страница 9: ...oisture entering the cabinet through the conduits Conduits that are installed to enter the top of the cabinet are most likely to cause water problems Installers should take reasonable precautions to prevent water from entering the cabinet Water damage is not covered under warranty 4 2 Wire Routing To avoid induced noise transfer of electrical energy from one wire to another keep input wiring isola...

Страница 10: ... an ordinary notification appliance circuit 4 3 2 Current Drawn from Battery Batteries used with the 5495 must not exceed 35AH 33AH max for FM Factory Mutual Installations Batteries larger than 7 AH will not fit into the 5495 cabinet and must be housed in the RBB Remote Battery Box See Section 4 7 for battery installation Table 4 1 Alarm Current Drawn From Main Control Panel Panel Voltage Current ...

Страница 11: ...m current 195 mA for 24 Hour Standby Current 39 mA for 60 Hours of Auxiliary Standby Current The above numbers were calculated assuming the use of 7 AH batteries at 100 of rated capacity The total current of the 5495 plus all items powered from it must not exceed 6 A when the panel is in alarm Use Table 4 2 to ensure that the current does not exceed 6 A and that the desired amount of standby is po...

Страница 12: ...vice manual for current ratings Alarm mA 0 mA mA Alarm mA 0 mA mA Alarm mA 0 mA mA Alarm mA 0 mA mA C Notification Appliance Current 0 mA mA D Total current ratings of all devices in system line A line B line C mA mA E Total current ratings converted to amperes line D x 001 A A F Number of standby hours 24 or 60 for NFPA 72 Chapter 1 1 5 2 5 24 Hrs for NBC section 3 2 7 8 H G Multiply lines E and ...

Страница 13: ... the control panel being used 4 4 1 Common Trouble Relay The 5495 has a Form C trouble relay built into Terminals 11 13 The relay provides a normally open and a normally closed contact both of which are rated at 2 5A The trouble relay will deactivate under any trouble condition A typical application of the trouble relay is to connect the 5495 normally closed N C contacts in series with the EOL sup...

Страница 14: ...sary since it is built into the 5495 board Class A Supervised Input Circuits The configuration shown in Figure 4 4 shows Class A supervised wiring from a fire alarm control panel to the 5495 board Pay close attention to the polarities when wiring a panel to the 5495 and follow these requirements When wiring to Terminal 18 on the 5495 you must use two separate wires Do not loop a single wire or twi...

Страница 15: ...iring methods for proper supervision Refer to the Appendix for notification appliances approved for use with the 5495 Class B Output Notification Circuits Figure 4 5 shows four 1 5 A devices wired as Class B Place a 4 7k ohm EOL resistor provided at the end of each circuit to enable supervision when using all outputs as Class B notification appliance circuits The 4 7k EOLs must be wired to the ter...

Страница 16: ...nd fault detection feature on the 5495 may interfere with the ground fault detection feature of the main control panel in the system To disable the ground fault detection feature on the 5495 place the jumper block on J1 across Pins 1 and 2 see Figure 4 2 4 7 Battery Connection Use two 12 VDC 7 AH gel cell batteries inside the 5495 cabinet For batteries larger than 7 AH not to exceed 35 AH use the ...

Страница 17: ...s A and Class B Auxiliary power state Which NACs to operate as steady ANSI temporal or sync outputs Refer to Figure 4 2 for the location of the DIP switch on the 5495 board 4 8 1 Selecting the Standard Input Output Configurations Figure 4 7 and Figure 4 8 show the position of each switch for the non synchronized input and output configurations The position of Switches 4 and 5 does not affect the r...

Страница 18: ...ote For 100 mS input signal debounce with no synchronization DIP switches 6 and 7 must be turned On 4 8 1 1 Input Output Configurations That Select ANSI Temporal Coded Outputs The DIP switch settings marked with an asterisk in Figure 4 7 and Figure 4 8 are designed to produce ANSI temporal coded outputs from a constant input The figures shown below compare the output patterns of ...

Страница 19: ...ons 4 8 2 1 4 8 2 2 or 4 8 2 3 4 8 2 1 Selecting Synchronized Faraday Configurations To select the input outputs for Faraday synchronized appliances set the DIP switches as shown in Figure 4 9 Figure 4 9 Faraday Synchronized Configurations Standard 5495 Input to Output Relationship Input Output Relationship for ANSI Temporal coded Options Important For all synchronization options input 1 is the st...

Страница 20: ...lecting Synchronized System Sensor Configurations To select the input outputs for System Sensor synchronized appliances set the DIP switches as shown in Figure 4 11 Figure 4 11 System Sensor Synchronized Configurations 4 8 2 4 Selecting Synchronized Wheelock Configurations To select the input outputs for Wheelock synchronized appliances set the DIP switches as shown in Figure 4 12 Figure 4 12 Whee...

Страница 21: ...t purposes only and the normal position for Switch 4 is OFF For testing the Low AC reporting you can temporarily turn Switch 4 ON without removing power Note Remember to turn the switch OFF when testing is complete Figure 4 14 Setting DIP Switch 4 4 8 4 Setting the Auxiliary Output Switch 5 on the DIP switch determines how the auxiliary power operates on the 5495 The 5495 checks Switch 5 only when...

Страница 22: ...arious 5495 configurations including daisy chaining 5 1 Notification Power Applications Figure 5 1 Input 1 Activates All Four Outputs Figure 5 2 Input 1 Activates NACs 1 and 2 Input 2 Activates NACs 3 and 4 5495 Local Fire Alarm Control Panel Local Fire Alarm Control Panel 5495 ...

Страница 23: ...ltiple power supplies are used with one control unit they will not sync with each other Figure 5 3 One Control Activating Two 5495s Figure 5 4 One Control Activating Three 5495s in Series 5495 5495 Local Fire Alarm Control Panel 5495 5495 5495 Local Fire Alarm Control Panel ...

Страница 24: ...es a dedicated 3 A auxiliary power output that you can select as non resettable output is always on See Section 4 8 4 for setting the auxiliary power If you need more than 3 A wire the inputs as shown in Figure 5 6 Figure 5 6 Auxiliary Output Wiring for Non Resettable Power 5495 5495 5495 Local Fire Alarm Control Panel ...

Страница 25: ...rm control panel that is programmed to open under alarm conditions See Section 4 8 4 for selecting auxiliary power options Figure 5 7 Door Holder Wiring Example Section 6 Troubleshooting Light emitting diodes LEDs indicate fault conditions This section describes the LED states 6 1 LEDs The eight LEDs indicate a fault in one of the circuits either NACs 1 through 4 auxiliary power earth fault low AC...

Страница 26: ... earth ground and one of the output circuit terminals is removed Power Limit At AUX Current draw at the auxiliary power terminals is exceeding 3 0 amps Power disconnects at the AUX terminal Input 1 and Input 2 supervision circuits open The yellow AUX LED lights The trouble relay is de energized The trouble restores when the overcurrent condition no longer exists When a circuit goes into a power li...

Страница 27: ...it is determined that the control panel needs to be repaired or replaced 6 4 1 Removing the Control Panel Follow these step to properly remove the control panel Table 6 1 Earth Fault Resistance Values by Terminal Function Terminal Number Terminal Label Value in kohms Auxiliary Devices 1 H5 AUX 0 2 H5 0 Notification Appliance Circuit 4 3 H4 OUT4 0 4 H4 0 Notification Appliance Circuit 3 5 H3 OUT3 0...

Страница 28: ... Panel Follow these steps to replace the control panel Note Use a grounding strap when working with static sensitive components 1 Align the control panel with the chassis mounting stand offs See Figure 6 1 2 Insert the four chassis mounting screws see Figure 6 1 Do not over tighten the chassis mounting screws 3 Insert the two heat sink screws see Figure 6 1 Do not over tighten the heat sink screws...

Страница 29: ...A 1 below lists notification appliances compatible with the 5495 Appliances which can be synchronized indicate the type of sync available in the columns marked Audio and or Visual Table A 1 Compatible Notification Appliances Manufacturer Model Audio Visual Type AMSECO SH24W 153075 x x Horn Strobe SAD24 153075 x Strobe SAD24 75110 x Strobe SL24W 75110 x Strobe SL24C 3075110 x Strobe SLB24 75 x Stro...

Страница 30: ...e Horn 5336 x x Multi Tone Horn Strobe 5337 x x Multi Tone Horn Strobe 5338 x x Multi Tone Horn Strobe 5343 x x Single Tone Horn Strobe 5346 x x Electronic Horn with Strobe 5347 x x Electronic Horn with Strobe 5348 x x Single Tone Horn Strobe 5373 x x 8 Tone Horn Strobe 6321 x x Sync Mini Horn Strobe 6322 x x Mini Horn Sync Strobe 6380 x 8 Tone Electronic Signal Strobe 5376 x x 8 Tone Horn Strobe ...

Страница 31: ... Strobe 5522 x 4 Square Sync Strobe 6120 x Horn 6140 x Horn 6223 x Horn 6226 x x Horn Strobe 6227 x x Horn Strobe 6228 x x Horn Strobe 6243 x Electron Mechanical Horn 6244 x Electron Mechanical Horn 6245 x Electron Mechanical Horn 6246 x x Electron Mechanical Horn Strobe 6247 x x Electron Mechanical Horn Strobe 6248 x x Electron Mechanical Horn Strobe 6300 x Mini Horn 6301 x Mini Horn 6302 x Mini ...

Страница 32: ...e P241575 FC x x Horn Strobe P241575W FC x x Horn Strobe P241575F FC x x Horn Strobe P241575K FC x x Horn Strobe P2430 FC x x Horn Strobe P2430W FC x x Horn Strobe P2430K FC x x Horn Strobe P2475 FC x x Horn Strobe P2475W FC x x Horn Strobe P2475K FC x x Horn Strobe P24110 FC x x Horn Strobe P24110W FC x x Horn Strobe P24110K FC x x Horn Strobe S2430W FC x Strobe S2430K FC x Strobe S2475 FC x Stro...

Страница 33: ...ndella Horn Strobe Ceiling Mount GCCR24 x Multi Candella Horn Strobe Ceiling Mount GCS24 x Multi Candella Strobe Ceiling Mount GCSR24 x Multi Candella Strobe Ceiling Mount GECR 24 x x Multi Candella Horn Strobe GES24 15 x Strobe GES24 30 x Strobe GES24 60 x Strobe GES24 75 x Strobe GES24 110 x Strobe GES24 15 75 x Strobe GES24 177 x Strobe GES3 24 x Multi Candella Strobe GESR 24 x Multi Candella S...

Страница 34: ... Horn Strobe P2RH x x 2 Wire Horn Strobe High Candela P2RH P x x 2 Wire Horn Strobe High Candela PC2RH x x 2 Wire Horn Strobe High Candela PC2RH P x x 2 Wire Horn Strobe High Candela P2W x x 2 Wire Horn Strobe P2W P x x 2 Wire Horn Strobe PC2W x x 2 Wire Horn Strobe PC2W P x x 2 Wire Horn Strobe P2WH x x 2 Wire Horn Strobe High Candela P2WH P x x 2 Wire Horn Strobe High Candela PC2WH x x 2 Wire Ho...

Страница 35: ... PC2WL x x Horn Strobe 2W WHT Ceil 4x4 P2GRL x x Horn Strobe 2W Red Wall 2x4 P2GWL x x Horn Strobe 2W WHT Wall 2x4 P4RL x x Horn Strobe 4W Red Wall 4X4 P4WL x x Horn Strobe 4W WHT Wall 4X4 PC4RL x x Horn Strobe 4W Red Ceil 4X4 PC4WL x x Horn Strobe 4W WHT Ceil 4X4 SR x Strobe SR P x Strobe SCR x Strobe SCR P x Strobe SRH x Strobe High Candela SRH P x Strobe High Candela SCRH x Strobe High Candela ...

Страница 36: ... Horn AH 12WP x Horn Weatherproof AH 24WP x Horn Weatherproof AMT 241575W x x Multi Tone Horn Strobe AMT 24MCW x Mutli Tone Horn Strobe AMT 241575W NYC x x Multi Tone Horn Strobe AMT 12 24 x Multi tone Horn AMT 12 24 NYC x Multi tone Horn AS 121575W x Horn Strobe NH 12 24 x x Horn AS 241575W x x Horn Strobe AS 24MCC x x Horn Strobe AS 24MCCH x x Horn Strobe AS 24MCW x x Horn Strobe AS 24MCWH x x H...

Страница 37: ... x Multitone Horn Strobe MTWPG 2475W x x Multitone Horn Strobe MTWPR 2475W x x Multitone Horn Strobe MTWPA 24MCCH x x Multitone Horn Strobe ZNH x Horn NS 121575W x x Horn Strobe NS 241575W x x Horn Strobe NS 24MCW x x Horn Strobe NS 24MCC x x Horn Strobe NS 24MCCH x x Horn Strobe ZNS MCW x x Horn Strobe ZNS MCWH x x Horn Strobe ZNS 24MCC x x Horn Strobe ZNS 24MCCH x x Horn Strobe RSS 121575W x Str...

Страница 38: ...trobe Weatherproof RSSWPR 24MCCH x Strobe Weatherproof RSSWP 2475W x Strobe Weatherproof RSSWP 2475C x Strobe Weatherproof RSSWP 24MCWH x Strobe Weatherproof ZRS MCWH x Strobe ZRS 24MCC x Strobe ZRS 24MCCH x Strobe MB G6 24 x Motor Bell MB G10 24 x Motor Bell MB G6 12 x Motor Bell MB G10 12 x Motor Bell MIZ 24 R x Mini Horn MT 12 24 R x x Multitone Horn MT4 12 2z x x Multitone Horn ZRS MCW x Strob...

Страница 39: ... ground Return the Honeywell Silent Knight product circuit board only Products that are returned in cabinets will be charged an additional 50 to cover the extra shipping and handling costs over board only returns Do not return batteries Honeywell has the authority to determine if a product is repairable Products that are deemed un repairable will be returned to the customer Product that is returne...

Страница 40: ...ANUFACTURER MAKES NO FURTHER WARRANTIES AND DISCLAIMS ANY AND ALL OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED WITH RESPECT TO THE PRODUCTS TRADEMARKS PROGRAMS AND SERVICES RENDERED BY MANUFACTURER INCLUDING WITHOUT LIMITATION INFRINGEMENT TITLE MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE MANUFACTURER SHALL NOT BE LIABLE FOR ANY PERSONAL INJURY OR DEATH WHICH MAY ARISE IN THE COURSE OF O...

Страница 41: ......

Страница 42: ...Silent Knight 12 Clintonville Road Northford CT 06472 1610 203 484 7161 Fax 203 484 7118 www silentknight com ...

Отзывы: