IMPORTANT:
The range and proper operation of any wireless device will
vary depending on its surroundings. It is very important that each CO5-
MC detector is tested with each receiver intended for alarm.
Detector Description
• Local
sounder
• Dual
LED’s
• Test/Hush
button
• Functional Gas Test
• Surface mount to wall or ceiling
• Optional drywall anchors included
The CO5-MC contains a piezoelectric horn which generates the ANSI
S3.41 temporal 4 pattern in an alarm condition (see note below Table
1 for temporal 4 pattern). In alarm, a message is also sent to a pro-
grammed Silent Call Receiver. The alarm message is transmitted every
4 seconds until the carbon monoxide condition has cleared and the de-
tector has reset. During an alarm condition, pressing the detector’s test
button will silence the piezoelectric horn for
fi
ve minutes. The mounting
base installation is simpli
fi
ed by the incorporation of features compat-
ible with drywall fasteners or other methods that provide a method for
securing the detector in place.
Two LEDs and a sounder on the detector provide local visual and audi-
ble indication of the detector’s status as listed in Table 1.
During initial power-up, the red and green LEDs will blink together once
every 10 seconds four times. It takes about 30 seconds for the detector’s