Installation

WARNING:

Installation should be

conducted by appropriately skilled and
authorised personnel only.

WARNING:

Ensure that power to the

instrument is switched off and signal
wiring isolated from hazardous voltages
before carrying out installation.

WARNING:

The instrument must be

installed in an enclosure that provides
adequate protection against electric
shock.

Location

¨

The instrument is designed for
installation in a clean, dry environment.

¨

Do not install near to switch gear,
motor controllers or other sources of
strong magnetic fields.

¨

Avoid exposure to direct sunlight and
ensure the ambient temperature inside
the enclosure that the unit is mounted
in will not exceed our specification.

Fixing

COM Series Modules are designed to be
be clipped to a mounting rail conforming
to BS5584:1978, EN50 022, DIN46277-3.
Hook the module onto the top edge of the
mounting rail and push in to engage the
clip onto the bottom of the rail.
The unit may be removed from the rail by
inserting a small bladed screw driver into
the release slot under the unit. Applying
gentle upward pressure to the handle of
the screwdriver will release the locking
tongue and enable the unit to be pushed
up and away from the mounting rail.

Dimensions

105 mm

Locking tongue
release slot

Access cover for
switch settings

»»

75

mm

22.5 mm

Mounting
Rail

span

power

zero

compact

SIL

Содержание COM-3B

Страница 1: ...SIGNAL ISOLATOR Type COM 3B User Guide Document Ref udcom 3b vp Rev 0...

Страница 2: ...tents Safety instructions warnings 1 Installation 2 Dimensions fixing 2 Wiring and connections 3 Power supply connections 3 Input and output connections 4 Input and output configuration 5 Specificatio...

Страница 3: ...not be exceeded If the instrument is used in a manner not specified the protection provided by the instrument may be compromised The instrument must be installed in an enclosure that provides adequate...

Страница 4: ...unlight and ensure the ambient temperature inside the enclosure that the unit is mounted in will not exceed our specification Fixing COM Series Modules are designed to be be clipped to a mounting rail...

Страница 5: ...ed on the top of the module Input connections are provided at the bottom of the module Power supply connections WARNING Check that the supply voltage on the data label on side of instrument is suitabl...

Страница 6: ...put connections current sink WARNING Current sink output is available only to order It is not available on the standard unit The data label on the side of the module will state whether this connection...

Страница 7: ...erminals see Input Connections Refer to the table and set switches SW2 1 and SW2 2 as appropriate for the input signal i e true zero or raised zero Setting output options Output signal Type Refer to t...

Страница 8: ...of full scale LOAD RESISTANCE EFFECT 0 001 of span 100 ohms change RESPONSE TIME 200 ms ISOLATION The input and output are isolated from each other and from the power supply Maximum voltage 250 V RMS...

Отзывы: