Some optional extensions and accessories 

 

Additional wireless 230V ‘Node’ sockets.

 For turning on/off any electrical appliance that 

starts  as  soon  as  it  receives  power.  Two  inputs  are  available  for  connecting  temperature 
sensors  or  detectors  (fire,  flooding,  burglary,  etc).  Wireless  communication  (433MHz) 
with the central unit. Available as Swiss socket (supporting up to 2300W) and “Schuko” 
socket (supporting up to 3600W, for Germany, Austria, Spain and many other countries).  
 

Wireless relays ‘GR-1’ and ‘GR-3’.

 Modules providing one, respectively three remote-

controlled  switches  (“potential-free  relays”  in  the  technical  language),  each  one  standing 
up to 3600W, centralized in your fuse-box or any other electrically insulated locker. Same 
functionality  as  a  “Node”:  temperature  surveillance,  thermostatic  regulation,  alarm 
transmission, etc. May replace an existing thermostat for target temperatures in the range 
from -29

°

C to +49

°

C (standard hystheresis: 1

°

C). 

 

230V  wall-mount  thermostats  ‘SI-2’.

  Ideally  suited  to  regulating  electric  heatings, 

including  electric  floor  heating  systems.  Two-pole  switch  standing  loads  up  to  16A 
(3600W).  Physical  dimensions  compatible  with  50x50mm  systems  (DIN  49075).  May 
replace  an  existing  thermostat  for  target  temperatures  in  the  range  from  -29

°

C  to  +49

°

(standard hystheresis: 1

°

C). 

 

Temperature sensors

 for ‘Nodes’ and ‘GR-1’ and ‘GR-3’ modules. Various lengths are 

available. Required for measuring and monitoring temperatures, as well as for thermostatic 
regulation. 
 

Wireless (RF) remote control

 for on-site steering of alarms, “Nodes” and other wireless 

peripherals. A-Comfort admits several remote controls in parallel.  
 
 
 

Wireless  and  cabled  detectors:  movement,  burglary,  fire,  gas,  water,  etc.

  The 

movement  detector  (PIR)  and  the  fire  detector  are  available  either  as  battery-driven 
wireless units, or as wired detectors to be plugged into a “Node” or a “GR-1” module. The 
other detectors are only available as cabled items. 

 

Backup battery

, which enables the central unit to cope with power outages. The battery is 

automatically  recharged  once  power  is  restored.  This  equipment  enables  A-Comfort  to 
emit alarms by SMS in case of power outage and power restoration. Moreover, the other 
alarm  functions  will  continue  to  work  for  many  hours  in  conjunction  with  any  wireless, 
batter-driven detectors. 

 

Siren

:  resounds  automatically  as  soon  as  a  detector  triggers  an  alarm  in  the  system. 

Available in two variants: either as a special version of the “Node” (for ease of installation) 
or of “GR-1” (as a fixed installation for enhanced security). 

 

 

These accessories and many other (e.g., GSM antennas) may be purchased from your Sikom dealer. 

Содержание A-Comfort

Страница 1: ...an electric heater is plugged into the wireless 230V socket and thus save energy by ensuring that the ambient temperature always is adapted to the situation see page 6 Set the temperature limits beyon...

Страница 2: ...s from any connected detectors and sensors to the central unit Temperature sensor For measuring temperatures Connect it to input 1 of your Node Wall bracket for the central unit Fix the central unit t...

Страница 3: ...rovider or else locked to the very operator that provided the SIM card 1 2 Check the validity of the SIM card still having the SIM card installed in the mobile phone ensure that you are able to 1 turn...

Страница 4: ...up to 64 of them Text of the SMS message the colours are here only to facilitate your understanding 1234 R011 This message is made up of two parts separated by a space character no spaces elsewhere 1...

Страница 5: ...simply executed sequentially in the textual order from left to right The status returned is therefore the state resulting from the preceding commands If the central unit is unable to communicate with...

Страница 6: ...you will simply switch between the lower and the higher scheduled temperature by means of the on off command R Command L010 will deactivate thermostatic regulation and revert to the manual control mo...

Страница 7: ...s attained or 01 Alarm Name 1 TempHi the upper limit is attained Detailed explanation of message contents 01 relevant Node number this tells you where in which room the issue occurred Alarm an alarm h...

Страница 8: ...mostat for target temperatures in the range from 29 C to 49 C standard hystheresis 1 C Temperature sensors for Nodes and GR 1 and GR 3 modules Various lengths are available Required for measuring and...