Main Functions (cont’d) 

 
Temperature surveillance 

 

By means of command 

S

01

 (requesting the status by SMS), you may at any moment read 

the  temperature  measured  by  your 

Node

 

(#01)

.  But  you  can  also  assign  to  it  the  task  of 

monitoring the temperature for you. This means that it will send you a notification by SMS 
if the ambient temperature exceeds either of the lower or upper limits chosen by you. This is 
a security mechanism, which may also be used in parallel to thermostatic regulation in order 
to  protect  against  a  malfunction  of  the  heating  device.  The  following  SMS  command  will 

activate

 temperature surveillance on your 

Node

 

(#01)

, with a 

lower limit

 

at

 +4°C

 and an 

upper limit 

at 

+22°C

 

1234 

T

01

1

+04

+22

 

 
NB: temperatures are always written with a ‘+’ or ‘-’ sign followed by two digits (e.g., +06 
for  +6°C). 
 
Command 

T

01

0

 will 

deactivate

 temperature surveillance on that 

Node (#01)

 

Temperature alarms by SMS take one of the following forms: 

 

01 Alarm. Name 1.TempLo

  (the lower limit is attained), or

 

 

01 Alarm. Name 1.TempHi

  (the upper limit is attained).

 

Detailed explanation of message contents:

 

 

01

:  relevant Node number; this tells you where (in which room) the issue occurred. 

 

Alarm

:  an alarm has been triggered. 

 

Name

:  name of the Node (cf. user manual for giving a name to your Node). 

 

TempLo

:  low temperature alarm. 

 

TempHi

:  high temperature alarm. 

 

NB:  Once a temperature alarm has been sent off, temperature surveillance is automatically deactivated. 

As  soon  as  the  cause  of  the  temperature  issue  has  been  corrected,  remember  to  reactivate  the 
surveillance. 

 
Prerequisites: 

 

A  temperature  sensor  must  be  plugged  into  input  #1  of  the  Node  to  enable  temperature 
surveillance. Temperature limits must be in the range from -29°C to +49°C. 

 

You have to register the phone number(s) to which temperature alarms are to be addressed. Please 
refer to the preparations on page 5 of this document. 

 

The « master alarm » switch must be active to enable the sending of temperature alarms by SMS. 
It is in principle always active and must only be temporarily deactivated during the installation of 
additional detectors such as fire, burglary, etc. Please refer to the user manual for the details. 

Содержание A-Comfort

Страница 1: ...an electric heater is plugged into the wireless 230V socket and thus save energy by ensuring that the ambient temperature always is adapted to the situation see page 6 Set the temperature limits beyon...

Страница 2: ...s from any connected detectors and sensors to the central unit Temperature sensor For measuring temperatures Connect it to input 1 of your Node Wall bracket for the central unit Fix the central unit t...

Страница 3: ...rovider or else locked to the very operator that provided the SIM card 1 2 Check the validity of the SIM card still having the SIM card installed in the mobile phone ensure that you are able to 1 turn...

Страница 4: ...up to 64 of them Text of the SMS message the colours are here only to facilitate your understanding 1234 R011 This message is made up of two parts separated by a space character no spaces elsewhere 1...

Страница 5: ...simply executed sequentially in the textual order from left to right The status returned is therefore the state resulting from the preceding commands If the central unit is unable to communicate with...

Страница 6: ...you will simply switch between the lower and the higher scheduled temperature by means of the on off command R Command L010 will deactivate thermostatic regulation and revert to the manual control mo...

Страница 7: ...s attained or 01 Alarm Name 1 TempHi the upper limit is attained Detailed explanation of message contents 01 relevant Node number this tells you where in which room the issue occurred Alarm an alarm h...

Страница 8: ...mostat for target temperatures in the range from 29 C to 49 C standard hystheresis 1 C Temperature sensors for Nodes and GR 1 and GR 3 modules Various lengths are available Required for measuring and...

Отзывы: