• Also fix cover strip’s  ends to avoid  uninten-
tionalpeeling.

Fig. 1: Mounting of the magnetic strip

Attention ! Do not expose the system to magne-
tic fields. Any direct contact of the magnetic
strip with magnetic fields (eg. adhesive magnets
or other permanent magnets) is to be avoided.
Sensor movements during power loss are not
captured by the follower electronics.

Mounting examples

Mounting with chamfered ends (fig. 2) is not
recommended unless the strip is installed in a
safe and protected place without environmental
influences. In less protected mounting places
the strip may peel. There we recommend moun-
ting accord. to fig. 3 and 4.

Mounting in a groove (fig. 5) best protects the
magnetic strip. The groove should be deep
enough to totally embed the magnetic strip.

Fig. 2

Fig. 3

Fig. 4

Fig. 5

3.2. Mounting the sensor

Use the two M3 screws to fix the magnetic
sensor  via the ø3.5 mm through holes.

• Cable layout should avoid damages due to
cable strain or other machine parts. If necessary
use a drag chain or protective hose and provide
for strain relief.

• Sensor must be aligned correctly with
respect to the counting direction 
(see fig. 6).
This can be ignored if counting direction can be
changed via the follower electronics (eg. by

magnetic display units from 

SIKO

).

• When mounting the magnetic sensor, ensure
that the gap between strip & sensor and the max.
admissable deviation are maintained over the
total measuring length! (see fig. 6)

• Maximal travel speed <10m/s

Fig. 6: Definition of counting direction / mounting

4. Electrical connection

• Wiring must only be carried out with power off!

• Check all lines and connections before swit-
ching on the equipment.

Interference and distortion

All connections are protected against the effects
of interference. The location should be selec-
ted to ensure that no capacitive or inductive
interferences can affect the sensor or the
connection lines!
  Interference can be caused
by motors, switch gear, cyclic controls and
contactors. Suitable wiring layout and choice of
cable can minimise the effects of interference.

Necessary measures:

• Only screened cable should be used. Wire cross
section is to be at least  0,14 mm

2

, max. 0,5 mm

2

.

• Wiring to the screen and ground (0V) must be
secured to a good point. Ensure that the connec-
tion of the screen and earth is made to a large
surface area with a sound connection to minimi-
se impedance.

Counting direction A before B

Gap between sensor and magnetic strip:
0,1- 4 mm

Max. deviation

< 1°

< 3°

< 3°

sensor’s travel direction

cable outlet

active side

Содержание MSK400

Страница 1: ...ieMontagemussplanzurMontagefl chebzw der zu messenden Strecke erfolgen Welligkei tenverschlechternimmerdieMessgenauigkeit berall wo aufgrund unzureichender Befestigungsm glich keiten keine geeignete M...

Страница 2: ...n getakteten Reglern oder Sch tzen vermindertwerden Klebebandesentfernen Abdeckbandaufkleben anbeidenEndenleicht berlappenlassen Die berlappendenEndendesAbdeckbandes gegen Abl sen sichern Abb 1 Montag...

Страница 3: ...Sensor und Nachfolgeelek tronik betr gt 30m AnschlussartE1 Anschluss mit offenen Kabelenden 1 Ummantelungentfernen 2 Schirmauftrennenundverdrillen 3 Litzen ca 5 mm abisolieren und verdrillen 4 Aderen...

Страница 4: ...nd Abb 6 ausgerichtet 6 Verl ngernvonMagnetb ndern MancheAnwendungsf llek nnendieVerl nge rung des Magnetbandes erfordern Mit einfa chen Hilfsmitteln besteht die M glichkeit das Magnetbandzutrennenund...

Страница 5: ...ic strip Themountingsurface measuringtrackmustbe flat Buckles or bumps will lead to measuring inaccuracies For applications which do not allow properly glueing of the magnetic strip it can be inserted...

Страница 6: ...to the counting direction see fig 6 This can be ignored if counting direction can be changed via the follower electronics eg by magnetic display units from SIKO Whenmountingthemagneticsensor ensure th...

Страница 7: ...o 10 over outer cable 2 Strip cable 3 Turndownscreening 4 Push part 5 onto ferrules 5 Solder wires to part 3 according connection diagram 6 Open spacer part 4 and put it over ferrules 5 screening as s...

Страница 8: ...art of strip Check polarity before joining the two parts Bothendsmustattracteachother ifnecessary use compass needle In case both ends have thesamepolarity shortenoneendbyahalfpole division fig 9 Join...

Отзывы: