Siko MSK2000 Скачать руководство пользователя страница 5

MB2000 

    Datum 09.11.2009 

Art.Nr. 81962 

Änd. Stand 326/09 

5

ENGLISH

Exemplary sensor illustrations are valid for all sen-
sor types unless described separately.

1.  Warranty information

In order to carry out installation correctly, we 
strongly recommend this document is read very 
carefully. This will ensure your own safety and 
the operating reliability of the device.
Your device has been quality controlled, tested 
and is ready for use. Please observe all warnings 
and information which are marked either directly 
on the device or specified in this document.
Warranty  can  only  be  claimed  for  components 
supplied  by  SIKO  GmbH.  If  the  units  are  used 
together with other products, the warranty for 
the complete system is invalid.
Repairs should be carried out only at our works. 
If any information is missing or unclear, please 
contact the SIKO sales staff.

2.  Identification

Magnetic strip:

 identification by printing on the 

strip.

e.g.    MSK2000-0023
 

 

       version number

 

 

       type of unit

3.  Installation

For mounting, the degree of protection specified 
must be observed. If necessary, protect the unit 
against environmental influences such as sprayed 
water,  dust,  knocks,  extreme  temperatures,  sol-
vents.

3.1 Mounting the magnetic strip

The mounting surface / measuring track must be 
flat. Buckles or bumps will lead to measuring in-
accuracies.

For applications which do not allow properly glueing of the magne-
tic strip,  it can be inserted into a 

profile rail

 (accessory) - eg.  rail 

type 

PS

 or 

PS1

 thus forming a compact mounting unit.

For  technical  reasons  the  strip  should  be  min. 
137mm longer than the actual measuring distance.

Attention!

  To  guarantee  optimal  adhesion  oil, 

grease dust etc. must be removed by using clean-
sing agents which evaporate without leaving re-
sidues. Suitable cleansing agents are eg. ketones 
(acetone) or alcohols; Messrs. Loctite and 3M can 
both supply such cleansing liquid. Make sure that 
the surface to be glued is dry and apply the strip 
with maximum pressure. Glueing should preferably 
be undertaken at temperatures between 20°C to 
30°C and in dry atmosphere.

Advice!

  When  applying  long  pieces  of  magnetic 

strip  do  not  immediately  remove  the  complete 
protective foil, but rather peel back a short part 
from the end sufficient to fix the strip. Now align 
the  strip.  As  the  protective  strip  is  then  peeled 
back and out press the tape firmly onto the moun-
ting  surface.  A  wall  paper  roller  wheel  could  be 
used to assist in applying pressure onto the mag-
netic strip when fixing it in position.

Mounting steps

 (see fig. 1)

Clean mounting surface (1) carefully.
Remove  protective  foil    (2)  from  the  adhesive 
side of the magnetic strip (3).
Stick down the magnetic strip (4).
Clean surface of magnetic strip carefully.
Remove protective foil (6) from adhesive tape on 
the cover strip (5).
Fix cover strip (both ends should slightly over-
lap).
Also fix cover strip's  ends to avoid  unintenti-
onalpeeling.




 

User Information

MB2000

Magnetic sensor and magnetic strip

pole pitch: 20mm
accuracy: 1mm
serial number

0

0

NNNN             2000

Magnetic sensor:

 The particular type of unit and 

type number can be seen from the identification 
plate. Type number and the corresponding version 
are indicated in the delivery documentation.

Содержание MSK2000

Страница 1: ...ferbare Pro lschiene z B Typ PS oder PS1 montiert werden Dadurch entsteht eine kompakte Magnetbandeinheit Aus technischen Gr nden muss bei der L nge gegen ber der Messstrecke ein Zuma von min 137mm be...

Страница 2: ...eilie genden Befestigungsschrauben und Federringe zu verwenden Anzugsmoment 0 25Nm Kabelsindsozuverlegen dasskeineBesch digungs gefahrdurchZugoderandereMaschinenteilebesteht Falls n tig Schleppkette o...

Страница 3: ...dung mit Schraubklemmverbindungen eingesetzt werden Signal nicht invertiert invertiert invertiert mit Referenzsignal A rot rot rot B orange orange orange I blau UB braun braun braun GND schwarz schwar...

Страница 4: ...htmagnetisierbar sein Der Sensor ist nicht oder nicht korrekt ange schlossen Pinbelegung Kap 5 Die Abstandstoleranz zwischen Sensor und Magnetband wurde nicht ber die gesamte Messstrecke eingehalten d...

Страница 5: ...mounting unit For technical reasons the strip should be min 137mm longer than the actual measuring distance Attention To guarantee optimal adhesion oil grease dust etc must be removed by using clean s...

Страница 6: ...er ferences can affect the sensor or the connec tion lines Interference can be caused by motors switch gear cyclic controls and contactors Sui table wiring layout and choice of cable can mini mise the...

Страница 7: ...d inverted inverted with reference signal A red red red B orange orange orange I blau UB brown brown brown GND black black black A yellow yellow B green green I violet Remove cable coating Open screen...

Страница 8: ...Toleranceforthegapbetweenmagneticsensorand magnetic strip not observed over the total travel distance Sensor touches strip see g 6 Cable squeezed interrupted cut by sharp edges Sensor s active side no...

Отзывы: