LE100/1
Installation English
LE100/1 · Date
10.09.2018 · Art.
No.
83230 · Mod.
status
232/18
21
4.3 Mounting the magnetic sensor
Alignment of the magnetic sensor
`
Take care that the magnetic sensor is aligned correctly in order to
ensure optimum sensing (see
Fig. 6
).
1. Mount magnetic tape (see chapter
4.2
).
2. Magnetic sensor can be fastened by using two bolts M3 over the elon-
gated holes (for the fastening dimensions refer to the Data Sheet). We
recommend to use the enclosed fixing screws and washer springs (fas-
tening torque = 1 Nm).
3. Place distance gauge with its complete surface between sensor and
magnetic tape. Note: only relevant for sensors without reference sig-
nal R.
LINEAR application:
LE100/1 with MB100/1:
1
Active side of the magnetic
tape
2
Travel direction sine before
cosine
3
Direction of outgoing cable
4
Admissible deviation of tape/
sensor
0.1 ... 0.4 mm reference point
O, IA, ID
0.1 ... 0.2 mm reference point
RB, RD
5
Maximum alignment error
6
Position of the reference point
relating to the marking on the
magnetic tape
* with fixed reference signal "RB"
MBxxxx GEK WT RP NNNNNN
<1°
<3°
(<1°*)
<3° (<1°*)
±0.5
Fig. 6: Definition of the counting direction with magnetic tape and
assemblage sensor / magnetic tape, gap measure, tolerances
NOTICE