GP43/44
Datum 10.08.2011
Art.Nr. 79804
Änd. Stand 243/11
9
Fig. 2: Cable preparation
Potentiometer/transducer
*Cam switch
Ferrule
Shink sleeve
GP43
GP44
Wire cross section:
- 2x0,25 mm² or 3x0,25 mm²
- * max. 7x0,5 mm² (number of cams x 2) +1
Ferrule
Shink sleeve
Fig. 3: Cable connection PG7
Fig. 7: Connection load against mass
follower electronics
Fig. 6: Pin connection with Instrument transformer
Output
transducer
Trip cams
Fig. 5: Pin connection without Instrument transformer
Potentiometer
Trip cams
Fig. 4: Cable connection PG9
With PG7 (fig. 3):
•
Push the nut (1) and the plastic bushing (2) onto
the cable.
•
Put the wire screening (3) over the plastic bu-
shing (2).
•
Slide strands through screw hole (4). Insert plastic
bushing (2) into the screw fitting.
•
Screw on the nut (1) and attach the complete
bolting (with O ring (5) for sealing) to the hood.
With PG9 (fig. 4):
•
Push nut+gasket (1), washer (2) (inner-ø >
washer's inner-ø (4)) and washer (4) onto the
cable.
•
Put the wire screening (3) over the washer's (2)
outer surface.
•
Push strands through the screw hole (5). Insert
parts (4), (3) and (2) into the screw hole (5).
•
Fix nut (1) and then fix the complete PG-screw
to the casing.
•
Connect strands to the clip terminals (fig. 5 and 6).
•
Close the geared potentiometer (see chapter 6.1).