DC connector – connect ONLY the (-) and (+):
Figure 2-6 DC Connector
2.8.2
DC Power Supply Notes
The DC power input range of the ODU is 36 - 57 VDC.
The DC supply should be limited to two ampere to avoid surges and possible
damage to the ODU. For that, use limited power supply or circuit breaker
(fast-blow fuse). The circuit-breaker is the disconnecting device, and should
be readily accessible.
When connecting the ODU to a MAINS DC distribution system, use a two
ampere circuit breaker to enable the central DC system to isolate the ODU in
an emergency case.
Use one poly circuit breaker and should connect it on the live voltage: (+) or
(-). The other poly should be grounded.
Connect the circuit breaker to the (+) or (-) live voltage.
The DC input is floating, so either (+) or (-) can be connected to the GND on
the power supply side. For the sake of consistency with other systems, Siklu
recommends that you connect the (+) to the GND.
Use a two-wire cable (14-18 AWG) to connect the power supply to the ODU.
On the ODU DC terminal, connect only the (+) and (-) wires. Do not connect
to the ODU's GND input.
Caution:
Disconnect all power cables before service!