DC2 'j' n
Execute Response Request
Code
12H 6AH n
Function Sends the execute response code as n if this command is executed.
n: response code (low order 4 bits are valid)
This interface has 4K bytes reception buffer and does not handle several operations such as the
commands, data input or execution or printing at the same time. Therefore, command or printing
termination can not be confirmed from outside.
By inserting this command the end of a command and/or print sequence and checking the
execute response code by this command, however, it is possible to confirm which commands
have been executed if the execute response code is responded.
Specify the execute response code as n. The code to be sent is the logical sum of the low order
4 bits of the specified n and the 50H and it will be the code of 50H to 5FH.