background image

Signify Classified - Internal

page

12/11/2019

2

Installation instructions

SLF – Slip Fitter Mount

TULS/TULM/TULL

Note: 

Tenon 

must be 3.75” or longer. 

ELECTRICAL CONNECTION 
1.

Connect the black fixture lead to the input voltage 

supply or Hot 1 (208V/240V/480V wiring).

2. 

Connect the white fixture lead to the neutral supply 

or Hot 2 (208V/240V/480V wiring). 

3. 

Connect the Green ground lead to the incoming 

ground wire. 

4. 

If Dimming is an option, connect the purple dimming 

positive lead to the supply dimming positive lead and 

the grey dimming negative lead to the supply dimming 

negative lead. 

SLF- SLIP FITTER MOUNT 

5. 

Remove splice cover screws and splice cover to 

access wire splice area.

6. 

Route the supply wire through the tenon. Secure the 

supply wire to keep from sliding back down the pole. 

Route wire through slip fitter arm into splice area.

7. 

Holding routed wires in splice area, carefully lower 

luminaire onto tenon. Check to ensure that wires are 

not pinched between inside of slip fitter and top of 

tenon and that luminaire and wires rotate.

NOTE

Install luminaire as per traffic direction label

Screws

Latches

11 ft.-lbs

Note: 7 pin NEMA Twist Lock Receptacle option aiming 
restricted to 0-90o per ANSI C136.10 