background image

Signify Classified - Internal

page

www.lightolier.com

TOP 

SPRINGS

BOTTOM  

SPRINGS

Fig. 6

1/28/2019

2

LyteSpan BoldFlood

INSTRUCTIONS FOR INSTALLING LOUVER 81LV4 :

1.

Turn off power to TRACK.

2.

First insert BOTTOM SPRINGS on the LOUVER into the BOTTOM GROOVE in the luminaire (Fig. 5 & 6)

3.

While pushing down TOP SPRING TABS, rotate LOUVER toward the TOP GROOVE in the luminaire until it hits the FRONT STEP on 
the luminaire. Release the TOP SPRING TABS into the TOP GROOVE (Fig. 5, 6, & 7).

4.

To remove, push down the TOP SPRING TABS and rotate away from the luminaire (Fig. 6).

NOTE: Ensure that all four LOUVERS SPRINGS are fully engaged for safe operation (Fig. 7).

IS:LWWJ20/LWWJ40

TOP SPRINGS

BOTTOM  
SPRINGS

SPRING TAB

Fig. 5

Fig. 7

FINAL LOUVER POSITION

GROOVE

GROOVE

SHORT 
TABS

SHORT 
TABS

Fig. 8

SUPPORT 

BEAM

VISOR

LUMINAIRE

Fig. 9

Rotate in directions as shown (Fig. 11)
Horizontal and vertical rotation have mechanical stops. 

DO NOT 

force past stops.

HORIZONTAL 
ROTATION

VERTICAL

ROTATION

Fig. 11

Fig. 10

FINAL POSITION OF VISOR

INSTRUCTIONS FOR INSTALLING  OPERATIONG VISOR 81VZ4:

1.

Place LONG TAB of visor in GROOVE. (Fig. 9 )

2.

Rotate VISOR toward Luminaire.

3.

Press SUPPORT BEAM enough to engage SHORT TABS into GROOVE. (Fig. 8)

4.

Ensure both LONG AND SHORT TABS are engaged in GROOVES in Luminaire. (Fig. 8)

5.

TO REMOVE: Press down on SUPPORT BEAM of VISOR and pull VISOR away from Luminaire.