background image

                WARNINGS AND INSTRUCTIONS FOR LUMINAIRES                 Page 1

 

IMPORTANT: 

FOR  YOUR  PROTECTION,  YOU  MUST  CAREFULLY  READ  ALL  WARNINGS  AND  INSTRUCTIONS  IN  THEIR  ENTIRETY  PRIOR  TO                     

INSTALLATION, OPERATION, SERVICE OR MAINTENANCE. FAILURE TO DO SO CAN RESULT IN DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. 
If  you  do  not  understand  these  warnings  and  instructions,  or  if  additional  information  is  desired,  please  contact  Signify  at                             

[email protected]

 

 

phone 800

-

227

-

0758.

 

• 

Installation, service and maintenance of luminaires must be performed by a qualified professional and in accordance with all  federal, state and 
local laws, regulations and electrical codes. This professional should be familiar with the construction and operation of this product and any haz-
ards involved.  If not qualified, do not attempt installation, service or maintenance.

 

• 

To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts, abrasions and other hazards, please 
read all warnings and instructions included with the luminaire, on the luminaire

s packaging and affixed to the luminaire itself.

 

• 

Maintenance  of  the  luminaires should  be  performed  by  person(s)  familiar  with  the  luminaire

s  construction  and  operation  and  any  hazards  in-

volved. 

 

 

CAUTION

 

 RISK OF PRODUCT DAMAGE

 

• 

Never connect luminaires and/or components under load with supply voltage turned on.

 

• 

Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation.

 

• 

Do not restrict fixture ventilation. Allow for some volume of airspace around luminaire. Avoid covering luminaire with insulation, foam or other material 
that will prevent convection or conduction cooling.

 

• 

Do not exceed luminaire maximum ambient temperature.

 

• 

Do not modify the luminaire.

 

• 

Only use luminaire in its intended application and location.

 

• 

Led products are polarity sensitive. Ensure proper polarity before installation.

 

• 

Electrostatic Discharge (ESD) can damage LED. Personal grounding equipment must be worn during all installation and servicing of the luminaire.

 

• 

Do not touch individual electrical components as this can cause ESD, shorten LED life, or impact LED performance.

 

• 

Some components inside the luminaire may not be serviceable. In the unlikely event your luminaire may require service, stop using it immediately and 
contact [email protected] phone 800

-

227

-

0758.

 

• 

Always read the luminaires complete installation instructions prior to installation for any additional luminaire specific warnings.

 

 

• 

In the case of HID or Fluorescent luminaires, regular re

-

lamping is required to keep luminaire operating within safe limits

 

• 

Do not install damaged product.

  Handling and installing damaged products can potentially increase the risks mentioned  In case of damage and/or 

missing parts upon arrival of the luminaire, please contact [email protected]

 

phone 800

-

227

-

0758.

 

• 

These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with 
installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for 
the purchaser

s or owner

s purposes, this matter should be referred to [email protected]

 

phone 800

-

227

-

0758.

 

• 

Please see luminaire specific Installation and Maintenance Instruction for additional warnings or any applicable FCC or regulatory statements. Failure to 
follow any of these Instructions could void luminaires warranties.

 

Luminaire Maintenance

 

• 

Regular luminaire maintenance programs are recommended.

 

• 

It is recommended to clean the outside of the luminaire and the refractor/lens. 

 

• 

Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. 

 

• 

If clean water is not sufficient for cleaning, use a neutral, synthetic, not

-

scratching and not

-

abrasive cleaning substance. 

 

• 

Never use alkaline and/or acetous cleaning substances. 

 

• 

Make sure that the cleaning substance is carefully removed by rinsing with lots of clean water. 

 

• 

Signify recommends using a cleaning solution that has a PH between 5 and 8.

 

• 

Recycle: For information on how to recycle electronic products and components, please visit www.epa.gov.

 

WARNING

 

RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY 

 

▪ 

Disconnect or turn off power before attempting any installation, 
service  or maintenance.

 

▪ 

Verify that supply voltage is correct by referencing the luminaire 
label information.

 

▪ 

Make all electrical and ground connections in accordance with 
the National Electrical Code (NEC) and any other applicable laws, 
regulations or codes.

 

▪ 

All wiring connections should be capped with UL

-

approved wire 

connectors.

 

WARNING

 

RISK OF FIRE OR PERSONAL INJURY

 

▪ 

Keep combustible materials away from LED/lamp & lens

 

▪ 

Do not operate in close proximity to persons, combustible       
materials or substances affected by heat or drying.

 

WARNING

 

RISK OF PERSONAL INJURY

 

▪ 

Wear gloves and safety glasses at all times when removing luminaire from 
carton, installing, servicing or performing maintenance.  

 

▪ 

Avoid direct eye exposure to the light source while it is on.

 

WARNING

 

RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY

 

▪ 

Allow Led/lamp & lens to cool before handling. 

 

▪ 

Do not touch enclosure or light source

 

▪ 

Do not exceed maximum wattage marked on luminaire label.

 

▪ 

Follow all manufacturer

s warnings, recommendations, instructions and 

restrictions for driver type, burning position, mounting locations and    
replacement.

 

Содержание GARDCO PowerForm

Страница 1: ...all damaged product Handling and installing damaged products can potentially increase the risks mentioned In case of damage and or missing parts upon arrival of the luminaire please contact SanMarcos...

Страница 2: ...ve owners www gardcolighting com STEP 1 To access wire splice area remove 2 8 32 Splice cover screws splice cover and gasket STEP 2 Route the supply wires through the Tenon Secure the supply wire to k...

Страница 3: ...Slip Fitter Arm Mounted on VERTICAL Tenon Cont d Note Tenon must be 4 00 or longer STEP 4 Using 3 8 Allen wrench hand tighten 4 Allen Socket Head bolts until tip of screws engage Tenon Do not fully ti...

Страница 4: ...ility for the structural integrity of the Mast Arm The EPA value of the luminaire CANNOT exceed the maximum loading value of the Mast Arm SlipFitter Arm Mast Arm by others STEP 1 Slip the SlipFitter A...

Страница 5: ...are owned by Signify Holding or their respective owners www gardcolighting com SF SlipFitter Arm Mounted on HORIZONTAL Mast Arm requires a 3 8 16 x 3 1 2 bolt thru Splice Area SlipFitter Arm Mast Arm...

Страница 6: ...as any commercial offer and does not form part of any quotation or contract All trademarks are owned by Signify Holding or their respective owners www gardcolighting com SF SlipFitter Arm Mounted on H...

Страница 7: ...produits endommag s peuvent potentiellement augmenter les risques mentionn s En cas de dom mage ou de pi ces manquantes sur r ception du luminaire veuillez communiquer avec SanMarcos TSC signify com o...

Страница 8: ...ion enlevez 2 vis n 8 32 de couvercle de jonction le couvercle de jonction et le joint TAPE 2 Faites passer les fils d alimentation travers le tenon Fixez le fil d alimentation afin qu il ne glisse pa...

Страница 9: ...voter jusqu la position de vis e horizontale appropri e Serrez les boulons jusqu environ 43 pieds livres TAPE 5 Effectuez la connexion des fils selon le Code national de l lectricit ou les codes locau...

Страница 10: ...g n est pas responsable de l int grit structurelle du bras du m t La valeur EPA du luminaire NE PEUT PAS d passer la valeur maximale de chargement du bras du m t Ces calculs doivent tre v rifi s Bras...

Страница 11: ...e raccord lisse MRL fix au bras HORIZONTAL du m t requiert un boulon de 3 8 16 x 3 1 2 travers le tuyau du bras du m t suite Zone de jonction Bras du montage raccord lisse Bras du m t par d autres tuy...

Страница 12: ...tre consid r e comme une offre commerciale et ne fait pas partie d aucun devis ni contrat Toutes les marques de commerce appartiennent Signify Holding ou leur propri taire respectif www gardcolightin...