background image

Document No DCP0002129 TC 26/03/02 Rev 4 

Technical Specification

 

PDA200E

 

Microphone input 

Impedance:                  Balanced 8k

 

                                     Unbalanced  5k

 

Sensitivity:                    - 65 dB 
Phantom power:           12V d.c. 
5 mm plug-on screw connectors. Sensitivity 65 dB. 

 

Line level input 

Impedance:                  Balanced ->20k

                                     Unbalanced –16k

 

Sensitivity:                    0 dB 

100V line input 

For direct connection to 100V line PA systems  
Impedance:                  > 20k

 

Sensitivity:                    +40 dB 

Input level control 

Line:                             -

 

to +3 dB  

Microphone                  -

 

to +45 dB

 

Tone control 

Mid range tone control with cut and boost function. 
Frequency:                   1 kHz 
Cut:                              -17 dB 
Boost:                           +17 dB 

Alert input 

For audible alert tone, triggered by switch to 12V 
DC 

Voltage input 

12V DC @  250 mA for triggering alert input and 
providing auxiliary power for outreach plates. 

Performance 

Bandwidth:                   100 Hz - 5 kHz @ 0 dB 
Dynamic range:            > 70 dB 
Noise:                           < -67 dB 
CMRR:                         > 84 dB 
Distortion:                     <0.33% THD @ 1 kHz 0 dBu

 

Mains voltage          

230V AC +10 / -20 % 

Dimensions

 

 

L x H x D                      273 mm x 200 mm x 77 mm 
Weight                          2.9 kg 

Power consumption 

< 80 VA 

Output drive current 

Max peak:                    > 8A 
EBU PPM:                    > 5.5A 
Sine 1 kHz:                   >2.1A RMS 
Loop coverage:            120m

2

 

Loop impedance:         0.2 to 2

 

Indicators 

Power on                      Green LED  
Audio in limit                 Red LED  
Loop Drive                    Yellow  LED

 

PDA200E Induction Loop System - 

Installation Guide

 

Page 7 

SECOND FIX 

Internal controls 

Three internal controls are located on the PCB, 
which is mounted on the lid of the PDA200E. 

The level control is used to set the input level into 
the amplifier. Apply a typical audio source, such as 
a CD or test signal, and adjust so that the limit    
indicator on the front panel just comes on, then 
move back approximately 1/8 of a turn.  

If this indicator is either on constantly, or not on at 
all (with the signal present), then the amplifier may 
need further adjustment. If this level is set too high 
then the life span of the amplifier may be             
significantly shortened. 

The drive control is used to increase or decrease 
the level of the output of the amplifier and should be 
set up after the limit has been set.  

It should be set so that the peak current ‘3’ indicator 
is either not on or is just occasionally flashing.     
Adjusting this control to the point where the peak 
current ‘3’ indicator is lit permanently may damage 
the amplifier. 

The tone control is used to improve intelligibility of 
speech or make the sound more ‘natural’.  

Turning the control clockwise boosts mid-range by 
up to +17 dB to improve speech intelligibility. 

Turning the control anti-clockwise cuts mid range 
by up to –17 dB and makes the sound more ‘warm’. 

Close the lid 

Secure using the 2 Allen bolts supplied. 

Test the system 

Apply a test signal and check that the system works 
satisfactorily. Ideally, the RxTI loop listener should 
be used or a national health hearing aid. 

Walk round the room and note areas where the  
signal is weak. BS7594 acknowledges that it may 
not be possible to cover all areas These areas 
should be marked to show the system is not     
available. 

Содержание PDA200E

Страница 1: ...ions at our discretion and without prior notice E OE Technical Features The PDA200E is a current mode induction loop amplifier with the following features Up to 120m2 coverage ideal for most applications Straightforward internal screw connections Ideal for electrical contractors no audio connectors Wall mounted for permanent installation Internal controls avoid user tampering Mid range tone contro...

Страница 2: ...oop Example Installation This schematic shows an example system which utilises a desk mounted microphone AMT wired direct into the PDA200E two wall mounted mics APM and a 100V line feed from a public address system The alert trigger has been wired to a doorbell which when activated plays a 2kHz tone through the loop ...

Страница 3: ...mpliance of the system as a whole Equipment guarantee This equipment is not guaranteed unless the system is installed and commissioned in accordance with national standards by an approved and competent person or organisation General precautions Do not test wiring with an insulation tester Megger with any equipment connected as the 500 Volt test voltage will destroy these devices totally Unpacking ...

Страница 4: ...V input is used these wires must also be segregated from the other inputs Mains Wiring Connect mains to the PDA200E The 230V a c cable MUST enter the enclosure via one of the knock outs at the top right hand corner of the enclosure This equipment requires fixed wiring using three core cable no less than 0 75 mm2 and no more than 2 5 mm2 fed from a 3 Amp fuse spur fitted with an all pole isolating ...

Страница 5: ...ach plate omitting the V connection Fitting Outreach Plates Up to five Outreach plates can be daisy chained together connected as a single line level input Mounting Outreach plates Outreach plates are supplied with cable and glands They are to be surface mounted on a 25 mm single gang box 1 Run the 2 pair screened audio cable supplied in kits from the PDA200E to the first Outreach plate and secure...

Страница 6: ...British Standard BS 7594 suggests several technically complex solutions that are reasonably effective but are rarely employed due to high cost A low cost but effective method to reduce overspill is to make a smaller loop typically in the centre of a room The smallest practicable loop for floor or ceiling mounting up to 3 metres high is 2 metres square This will provide a reasonable field at head h...

Страница 7: ...control is used to set the input level into the amplifier Apply a typical audio source such as a CD or test signal and adjust so that the limit indicator on the front panel just comes on then move back approximately 1 8 of a turn If this indicator is either on constantly or not on at all with the signal present then the amplifier may need further adjustment If this level is set too high then the l...

Страница 8: ...or wall ceiling APJ 3 5 mm mono jack plate for unbalanced microphones APX XLR plate for hand mics mixing desks APL line level for TV sets or other audio Up to 5 Outreach plates can be daisy chained together as illustrated below Accessories Available separately AMT Tie Clip Desk mic AMH Handheld mic AML Lectern mic AMD Desktop mic AMP Phantom powered condenser microphone AMR Handheld or Lavaliere r...

Отзывы: