Microphone 

The microphone is a noise-cancelling dynamic microphone designed for close-talking, hand-held 
applications in quality sound installations where background noise is a problem. The frequency 
response, especially tailored for voice communications, provides a crisp, clear, highly intelligible sound 
with 360 degrees minimization of background noise. A soft lip guard is positioned to assure proper close 
talk voice spacing by the operator. It offers extreme reliability, convenient handling, rugged construction 
and high performance for years of dependable service. The dynamic cartridge has a rugged polyester 
diaphragm which resists moisture, temperature extremes, most acids, alkalis and solvents. Molded in 
high impact Cycolac, it comes with a permanently attached, heavy duty, four-conductor, two shielded, 
coil cord and a simple to operate DPDT long life, trouble free switch. It has a low-impedance output and 
is factory wired normally open.  

Element: Dynamic noise cancelling 

Frequency Response: 100 to 5000 Hz 

Output Level: -58 dB (0 dB = 1mw / 10 microbars); -80 dB (0 dB = 1 volt / microbar); 1.0 mV/PA 

Impedance: 200 ohms, matches 50 to 1000 ohms 

Cable: Four conductor, two shielded, permanently attached, heavy duty, coil cord that extends to 1.8m 

Switch: Operated by press-to-talk lever, DPDT long life, trouble free switch with spring return, has 
smooth feel.  

Housing: Durable moulded black Cycolac 

Dimensions: 100mm (3-15/16") high x 75.4mm (2-3/32) wide x 66.7mm (2-5/8") deep 

Weight: 284 grams 

 

 

 

 

SigNET AC Limited 

6 Tower Road, 
Glover Estate, 
Washington, 
Tyne & Wear, 
NE37 2SH. 
Tel: 0191 417 4551 
Fax: 0191 417 0634 

 

+10 

-10 

50     100       200           500       1K         2k            5k        10k       20k 

Response in dB 

Frequency in hertz 

Содержание FMIC

Страница 1: ...a close talking noise cancelling fist microphone plus ancillary electronics It is designed to be used with SigNET s Integrity voice alarm system and is fully monitored for faults The internal electronics comprise two parts a 1ZPR pre amplifier and monitoring unit and an FMX fault monitoring expansion and message control unit Up to four FMICs may be connected in a daisy chain format to one voice al...

Страница 2: ...a correctly configured Integrity VA system Press the Message 1 PLAY button and the associated LED lights briefly The message normally Evacuate plays once and will stop when it reaches the end The message 2 controls and indicators are the same except that a Test message is normally controlled Technical description Speech is picked up by the microphone and the signals are passed to a voltage control...

Страница 3: ...at 5 lead from the terminal block remove the back plate and keep it safe The FMIC should be located in an area that will be as quiet as possible in an emergency Fix the box to the wall normally between 1 2 and 1 4 metres from the final floor position using suitable fasteners In the UK standard or enhanced fire rated cables BS 5839 1 2002 should be used FMX 1ZPR Eight back plate screws VU meter unp...

Страница 4: ... fitting more than one FMIC joint the cables in a separate connection block and then use connect to the FMIC using short tails FMIC Connections 24 V 0 V PTT Busy Switch 1 Switch 2 Audio Audio 24 V 0 V PTT Busy Switch 1 Switch 2 Audio Audio FMIC 1 FMIC 2 FMIC 3 FMIC 4 1 2 3 4 OFF ON OFF ON OFF ON Mic control SW1 control SW2 control ON FMX switch settings One FMIC fitted Two FMICs fitted Three FMICs...

Страница 5: ...vels as necessary Refit the back plate and close the door Check that the FMX POWER light is lit and the FAIL light is off Check that the 1ZPR POWER light is lit and the FAULT light is off Finally test the MIC PTT switch and the message play controls Locks All FMICs are provided with the same key to pass A T Bar option is available at extra cost however this is not recommended for public places Con...

Страница 6: ... operational The Equalization Tone controls 3 Bass 100 Hz Mid 1 kHz and Treble 10 kHz tone controls with 12 dB of adjustment are provided They can be used to improve intelligibility and reduce the effects of feedback Start by setting the bass and treble to minimum fully anti clockwise and the mid control at maximum Then adjust to get the best results Master and Chime levels 4 Adjust the chime cont...

Страница 7: ...phone FAULT lit when a fault is detected in the 1ZPR or its associated microphone Combined VU BUSY indicator Lights solid green to say that another mic on the same line is busy LEDs follow the sound picked up by the microphone External controls Push to Talk button SPEAK EQ filters 100 Hz 12 dB 1 kHz 12 dB 10 kHz 12 dB Compression ratio 3 1 Noise gate threshold 30 dB Master and chime levels to 4 dB...

Страница 8: ...ds alkalis and solvents Molded in high impact Cycolac it comes with a permanently attached heavy duty four conductor two shielded coil cord and a simple to operate DPDT long life trouble free switch It has a low impedance output and is factory wired normally open Element Dynamic noise cancelling Frequency Response 100 to 5000 Hz Output Level 58 dB 0 dB 1mw 10 microbars 80 dB 0 dB 1 volt microbar 1...

Отзывы: