MAINTENANCE
Application Guidelines/Water Supply
Parameters
Service Flow
0.5 gpm (1.9 lpm)
Water Supply
Community or Private Well -
Potable Water
Water
Pressure
20 – 120 psi (138 – 827 kPa)
Water
Temperature
33 °F – 100 °F (0.6 °C – 37.8 °C)
Capacity
200 gallons (757 liters)
It is essential that the manufacturer’s recommended
installation, maintenance and filter replacement
requirements be carried out for the product to perform
as advertised.
NOTE
•
While the testing was performed under standard
laboratory conditions, actual performance may vary.
Replacement Cartridge:
LT1000P (ADQ74793501)
LT1000PC (ADQ74793504)
LT1000PCS (ADQ74793505)
For replacement filters, visit your local dealer or
distributor or search under “water filters” on the
lg.com
website.
For further assistance, the LG Electronics Customer
Information Center is open 24 hours a day/7 days a
week.
USA: 1-800-243-0000C
anada: 1-888-542-2623
LG is a trademark of LG corp.
NSF is a trademark of NSF International.
Manufactured for LG Electronics by:
LG Electronics, INC
170, Sungsanpaechoungro, Seongsan-gu,
Gyeongsangnam-do, THE REPUBLIC OF KOREA
WARNING
To reduce the risk associated with choking:
•
Do not allow children under 3 years of age to
have access to small parts during the installation
of this product.
To reduce the risk associated with the
ingestion of contaminants:
•
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system. Systems
certiied for cyst reduction may be used on
disinfected water that may contain ilterable
cysts. EPA Establishment # 070595-MEX-001
CAUTION
To reduce the risk associated with property
damage due to water leakage:
•
Read and follow Use Instructions before
installation and use of this system.
•
Installation and use MUST comply with all state
and local plumbing codes.
•
Do not install if water pressure exceeds 120 psi
(827 kPa). If your water pressure exceeds 80
psi, you must install a pressure limiting valve.
Contact a plumber if uncertain how to check your
water pressure.
•
Do not install where water hammer conditions
may occur. If water hammer conditions exist you
must install a water hammer arrester. Contact a
plumbing professional if you are uncertain how
to check for this condition.
•
Do not install on hot water supply lines. The
maximum operating water temperature of this
ilter system is 100 °F (37.8 °C).
•
Protect ilter from freezing. Drain ilter when
temperatures drop below 40 °F (4.4 °C).
•
The disposable ilter cartridge MUST be replaced
every 6 months, at the rated capacity or if a
noticeable reduction in low rate occurs.
•
Protect from freezing, remove ilter cartridge
when temperatures are expected to drop below
33 °F.
•
Do not install systems in areas where ambient
temperatures may go above 110° F (43.3 °C).
•
Where a backlow prevention device is installed
on a water system, a device for controlling
pressure due to thermal expansion must be
installed.
•
Ensure all tubing and ittings are secure and free
of leaks.