INSTALLATION INSTRUCTIONS
dimensions and Clearances
CAUTION
To eliminate the risk of burns or fire by reaching over heated surfaces, cabinet storage space located above
the cooktop should be avoided.
If cabinet storage is provided, risk can be reduced by installing a range hood that projects horizontally a
minimum of 5" (127 mm) beyond the face of the cabinets.
Overhead cabinet should not exceed a maximum
depth of 13" (330 mm).
Min. from edge of
cooktop to nearest
combustible wall
(either side of unit).
Empty space is needed underneath
the cooktop for installation purposes.
Approximate location
of junction box.
12"
(305 mm)
10"
(254 mm)
3
3
/
4
"
(95 mm)
34
9
/
16
"
(878 mm)
5
23
/
32
" Min. (145 mm)
18"
(457 mm)
36" Min
(914 mm)
24"
(610 mm)
Min. recommended
distance between
rear edge of
cutout and nearest
combustible
surface.
9
11
/
16
"
(500 mm)
2
1
/
2
" Min. (64 mm)
Recommended Spacing between Cooktop and Oven
CAUTION
It is very important to keep 2
3
/
4
" (70 mm) distance between the cooktop and the oven.
2
3
/
4
" (70 mm)