Signamax
™
10/100TX to 100FX Media Converter
8
User’s
Manual
Link-Fault-Pass-Through
Connect the FX ports of two Media Converter A and B
through the fiber cable.
Link Fault of the FX port:
A Link Fault condition will be sensed on the TX port
whenever the media converter detects a Link Fault condition
on the FX port. Thus, the 100, LNK/ACT, and FDX/COL
LEDs of the media converter would be off.
Link Fault of the TX port of the Media Converter A:
The Media Converter A: A Link Fault condition will be sensed
on the FX port whenever the media converter detects a Link
Fault condition on the TX port. Thus, the 100, LNK/ACT, and
FDX/COL LEDs of the TX port of the Media Converter A
would be off.
The Media Converter B: A Link Fault condition will be
informed to the FX port of the Media Converter B. Then a
Link Fault condition will be sensed on the TX port of the
Media Converter B whenever the Media Converter B detects
a Link Fault condition on the FX port. Thus, the 100,
LNK/ACT, and FDX/COL LEDs of the Media Converter B
would be off.
Link Fault of the FX port
TX Port
FX Port
LEDs
PWR 100 LNK/ACT FDX/COL LNK/ACT FDX/COL
Media Converter A ON OFF OFF
OFF
OFF
OFF
Media Converter B ON OFF OFF
OFF
OFF
OFF
Link Fault of the TX port of the Media Converter A
TX Port
FX Port
LEDs
PWR 100 LNK/ACT FDX/COL LNK/ACT FDX/COL
Media Converter A ON OFF OFF
OFF
ON
ON
Media Converter B ON OFF OFF
OFF
OFF
OFF