Installation
The site where you place the switch may greatly affect its performance. When installing, take the
following into your consideration.
2.1 Installation method
Follow the guidelines below to install the Switch.
Install the Switch in a fairly cool and dry place. See the Technical Specifications for the acceptable
temperature and humidity operating ranges.
Install the Switch on a sturdy, level surface that can support its weight, (at least 4KG)
Connect the power cord to the Switch and the power outlet. The distance is no more than 182cm.
Leave at least 10cm (about 4 inches) of space at the front and rear of the Switch for ventilation.
2.2 Desktop or Shelf Installation
When installing the Switch on the desktop or shelf, please attach the rubber feet to the Switch.
Peel off the protective paper on the pads and attach them on the bottom of the Switch (one at each
corner).
2.3 Rack Installation
The Switch is rack-mountable and can be installed on an EIA-19 inch equipment rack. To do this,
first install the mounting brackets on the Switch’s side panels (one on each side), secure them with
the included screws, and then use the screws provided with the equipment rack to mount the
Switch on the 19inch rack.
2.4 Power on the Switch
The Switch has a universal power supply ranging from 100V to 220V AC, 50 ~ 60Hz power source.
The AC power connector is located at the rear of the unit adjacent to and the system fan. The
switch’s power supply will adjust to the local power source automatically.