background image

Signamax Connectivity System      ______________________________________________    065-1197A

 

 

WWW.SIGNAMAX-US.COM

 

WWW.SIGNAMAX-CE.COM

 

FCC Warning 

 

This device has been tested and found to comply with limits for a 
Class A digital device, pursuant to Part 2 and Part 15 of the FCC 
Rules.    These  limits  are  designed  to  provide  reasonable 
protection  against  harmful  interference  when  the  equipment  is 
operated  in  a  commercial  environment.    This  equipment 
generates,  uses  and  radiates  radio frequency  energy and,  if  not 
installed  and  used  in  accordance  with  the  user’s  manual,  may 
cause interference in which case user  will be required to correct 
the interference at his own expense. 

NOTICE: 

1. The changes or modifications not expressively approved 

by the party responsible for compliance could void the 
user's authority to operate the equipment. 

2. Shielded interface cables and AC power cord, if any, 

must be used in order to comply with the emission limits. 

 

CISPR A COMPLIANCE: 

 

This device complies with EMC directive of the European 
Community and meets or exceeds the following technical 
standard. 

 

EN 55022 

- Limits and Methods of Measurement of Radio 

Interference Characteristics of Information Technology 
Equipment. This device complies with CISPR Class A. 
 

WARNING: 

This is a Class  A product. In a domestic environment, this 
product may cause radio interference in which case the user 
many be required to take adequate measures. 

Содержание 065-1197

Страница 1: ...m ______________________________________________ 065 1197A WWW SIGNAMAX US COM WWW SIGNAMAX CE COM Signamax Connectivity Systems Gigabit Ethernet media converters 1000Base T to 1000Base SX LX series Model 065 1197A User s Manual ...

Страница 2: ...will be required to correct the interference at his own expense NOTICE 1 The changes or modifications not expressively approved by the party responsible for compliance could void the user s authority to operate the equipment 2 Shielded interface cables and AC power cord if any must be used in order to comply with the emission limits CISPR A COMPLIANCE This device complies with EMC directive of the...

Страница 3: ...A WWW SIGNAMAX US COM WWW SIGNAMAX CE COM Table of contents Chapter 1 4 Introduction 4 Product Features 5 Technical Specifications 6 Chapter 2 7 Package contents 7 Model information Chyba Záložka není definována Chapter 3 8 Installation 8 The LED indicators 8 Chapter 4 9 Application 9 ...

Страница 4: ...tend the connection distance between two Gigabit Ethernet Twisted pair devices via fiber cable transparently with no performance degradation The Gigabit converter series is supported 1000Base T Auto negotiation Auto MDIX Isn t working in the 10Base T or 100Base TX environment The converters supported flow control function both on Twisted pair port and Fiber port And provided different types of fib...

Страница 5: ...e or 6 twisted pair cable Supports Full duplex operation Gigabit Std Switch base design support flow control capability 1000Base SX interface for up to 220 meters Multi mode 62 5 125 µm MMF optic cable 1000Base SX interface for up to 550 meters Multi mode 50 125 µm MMF optic cable 1000Base LX interface for up to 40 km Single mode 9 125 µm SMF optic cable LED indicator supports Multiple fiber conne...

Страница 6: ...support Twisted pair STPà100 meters 328ft 220m for 62 5 125 µm MMF optic cable 550m for 50 125 µm MMF optic cable 40km for 9 125 µm SMF optic cable Wavelength 850nm for 1000Base SX 1310nm for 1000Base LX Data Transfer Rate 1000Mbps LED indicators System power Twisted pair port Link TX LEDs Fiber port Link RX LEDs Temperature 0 to 60 Operating 20 to 90 Storage Humidity 10 to 90 Non condensing Power...

Страница 7: ...____________________ 065 1197A WWW SIGNAMAX US COM WWW SIGNAMAX CE COM Chapter 2 Package contents Before you start to install the converter please verify your package that contains the following items One media converter One Power Adapter One User s Manual ...

Страница 8: ...TP port The TP port of converter supported 1000Base T Auto negotiation Auto MDIX and Flow control function Please make sure isn t working in the 10Base T or 100Base TX environment The cable length up to 100 meters for Cat5 5e or 6 shielded unshielded twisted pair cable III The Fiber port The converter provided different types of fiber connectors such as SC LC GBIC and SFP LC for multi mode or sing...

Страница 9: ...amax Connectivity System ______________________________________________ 065 1197A WWW SIGNAMAX US COM WWW SIGNAMAX CE COM Chapter 4 Application Multi Mode Fiber MMF application Single Mode Fiber application ...

Отзывы: