I/O cables, MI/1020 can be ordered separately to connect to the Relay outputs. (Previously,
MI/996)
Relay specification
•
Load:
Resistive load (cosφ = 1)
•
Rated Load: 0.5 A at 125 VAC; 1 A at 24 VDC
•
Contact Material: Ag (Au alloy)
•
Rated Carry Current: 2 A
•
Max. switching voltage: 125 VAC, 60 VDC
•
Max. switching current: 1 A
•
Max. switching power: 62.5 VA, 30 W
•
Failure rate (reference value): 1 mA at 5 VDC
‒
P level: λ60 = 0.1 x 10
-6/operation. This value was measured at a switching frequency of
120 operations/min and the criterion of contact resistance is 100. This value may vary
depending on the operating environment. Always double-check relay suitability under
actual operating conditions