- 22 -
Pic 3.2.1.1 set the time section
【
Interval
】
Only one alarm signal is turned on even there are several motion detect signals in the set
interval.
【
Alarm output
】
Start the external equipment of corresponding linkage alarm when the motion detect
alarm is turned on.
【
Delay
】
Delay a few moments and stop when the alarm state is turned off. The range is 10~300
seconds.
【
Record channel
】
Choose the recording channel (multiple option supportive). Trigger the video
signal when the alarm is turned on.
Note:Set in the [Record Conf] and perform the linkage recording. Start detecting video files in the
corresponding time section.
【
Tour
】
■
means that the selective channel is single window alternate patrol preview. The interval is
set in the [Main Menu]>[System] > [Tour].
【
PTZ Activation
】
Set the PTZ activation when the alarm is turned on.
Note
:
to link PTZ, need go [Shortcut menu]->[PTZ control] to set preset point, tour & interval time
etc.