Signal 400 Скачать руководство пользователя страница 5

 

 

RF output level 

-14 ~ +6dBm, 0.1db step 

System 

Management 

LCD + control buttons 

Language   

English   

LCN Insertion 

yes 

Upgrade 

USB 

General

 

Power supply 

DC 12V 

Dimensions 

183*110*50mm 

Weight   

< 1kg 

CHAPTER 2 Safety Instruction and Installations 

Safety Instructions 

WARNING: Hot plug is not allowed since it may cause system halted. 

To prevent fire or electrical shock, do not expose the device to rain or moisture. 

 

  The encoder modulator is powered with a voltage of 12V DC. The power supply voltage 

must not exceed the recommended voltage, which otherwise may cause irreparable damage 

to the device and the invalidation of the warranty. Therefore:   

 

Do not replace power supply with a voltage greater than 12V DC.   

 

Do not connect the device to the power if the power cord is damaged.   

 

Do not plug the device into mains supply until all cables have been connected correctly.   

 

Do not cut the cord.   

Avoid  placing  the  device  next  to  central  heating  components  and  in  areas  of  high 

humidity.   

Do not cover the device with elements that obstruct the ventilation slots.   

If the encoder modulator has been kept in cold conditions for a long time, keep it in a warm 

room minimum 2 hours before plugging into the mains.   

Mount the device in vertical position with the connectors located on the top side.   

When replacement parts are required, be sure the service technician has used replacement 

parts  specified  by  the  manufacturer  or  have  the  same  characteristics  as  the  original  part. 

Unauthorized substitutes may result in fire, electric shock or other hazards. 

Safety  check-  Upon  completion  of  any  service  or  repairs  to  this  device,  ask  the  service 

technician to perform safety checks to determine that the device is in proper condition. 

Содержание 400

Страница 1: ...Signal 400 HDMI COFDM DVB T Encoder Modulator Home Use ...

Страница 2: ... best conditions of performance Keep this manual for future reference Directory CHAPTER 1 Product Introductions 3 General Description 3 Working Principle 4 Technical Specifications 4 CHAPTER 2 Safety Instruction and Installations 5 Safety Instructions 5 Installations 6 CHAPTER 3 Operations and Management 7 CHAPTER 4 How to Upgrade 11 Appendix 12 ...

Страница 3: ... Digital Signage shops etc It is an all in one device integrating MPEG 4 AVC H 264 encoding and modulating to convert audio video signals into DVB T RF out The signals source could be from satellite receivers closed circuit television cameras Blue ray players and antenna etc its output signal is to be received by a DVB T standard TVs or STBs etc DC 12V Grounding RF out RF mix in USB Port for Upgra...

Страница 4: ...PS 1080p 25FPS 1080i 59 94 60FPS 1080p 30FPS 1080p 59 94 60FPS 1080p 30FPS Aspect Ratio 16 9 5 4 Bit rate 1 000 18 000 Mbps Audio Encoding MPEGI layer 2 MPEG 2 AAC Sample rate 48KHz Bit rate 64 96 128 192 256 320kbps DVB T Modulator Section Standard DVB T COFDM Bandwidth 6M 7M 8M Constellation QPSK 16QAM 64QAM Code rate 1 2 2 3 3 4 5 6 7 8 Guard Interval 1 32 1 16 1 8 1 4 Transmission Mode 2K 8K M...

Страница 5: ...cord is damaged Do not plug the device into mains supply until all cables have been connected correctly Do not cut the cord Avoid placing the device next to central heating components and in areas of high humidity Do not cover the device with elements that obstruct the ventilation slots If the encoder modulator has been kept in cold conditions for a long time keep it in a warm room minimum 2 hours...

Страница 6: ... The signal source can be from a surveillance monitor DVD set top box CCTV and etc 3 O ptionally connect the loop through RF input coaxial cable 4 Connect cable to RF output to STB TV 5 Power supply connection a Connect the earth cable b Connect the power plug to the unit mains connector c Connect the power plug to the mains socket Cascade Installation SIGNAL 400 unit has 1 TV signal to RF output ...

Страница 7: ...eft Right Up Down buttons Use these buttons to turn the screen pages shift the target items by moving the triangle or change the parameter settings in the program mode Enter Use this button to enter a submenu or save a new setting after adjustment press it to start adjusting the value of certain items with Up Down buttons when the corresponding underline flash Hue 1 Hue 001 Hue 001 Hue 002 Enter P...

Страница 8: ...present setting or not If not the LCD will display the current configuration state When the power is connected the LCD will start to initialize the program The LCD menu goes as below chart ...

Страница 9: ...EC 7 8 15 Main Menu System System Save Config System Load Saved CFG System Lock Keyboard System Product ID System Version Save Config Yes No Load SavedCFG Yes No Lock Keyboard Yes No 0035564905656 70ec8f7b0000f Encoder Modulator Ver 1 01 Main Menu Stream Stream TSID ONID Network ID Network Name Service Name Provider name Program number LCN PMT PID Video PID Audio PID System Factory Reset System LC...

Страница 10: ...efault Australia or New Zealand If user chooses Default modulating parameters need to be set manually through advanced configuration If choose other two user do not need to set RF frequency Bandwidth Constellation FEC FFT Guard interval and RF Level It will configure automatically according to the Country It is a shortcut 7 Channel User can choose Channel under this submenu 8 Bit Rate User can rea...

Страница 11: ... is required to input the password to unlock the key board This operation is one off Password forgotten please use the universal code 005599 22 Product ID User can view the serial number of this device It is read only and unique 23 Version It displays the version information of this device Encoder Modulator the name of the device Ver version number of this device CHAPTER 4 How to Upgrade SIGNAL 40...

Страница 12: ...19 5 223 C53 701 704 5 708 C12 223 226 5 230 C54 708 711 5 715 C55 715 718 5 722 UHF C56 722 725 5 729 C57 729 732 5 736 C20 470 473 5 477 C58 736 739 5 743 C21 477 480 5 484 C59 743 746 5 750 C22 484 487 5 491 C60 750 753 5 757 C23 491 494 5 498 C61 757 760 5 764 C24 498 501 5 505 C62 764 767 5 771 C25 505 508 5 512 C63 771 774 5 778 C26 512 515 5 519 C64 778 781 5 785 C27 519 522 5 526 C65 785 7...

Страница 13: ...5 9 95 11 06 11 71 12 06 2 3 9 95 11 05 11 70 12 06 11 61 12 90 13 66 14 07 13 27 14 75 15 61 16 09 3 4 11 19 12 44 13 17 13 57 13 06 14 51 15 36 15 83 14 93 16 59 17 56 18 10 5 6 12 44 13 82 14 63 15 08 14 51 16 12 17 07 17 59 16 59 18 43 19 52 20 11 7 8 13 06 14 51 15 36 15 83 15 24 16 93 17 93 18 47 17 42 19 35 20 49 21 11 64QAM 1 2 11 19 12 44 13 17 13 57 13 06 14 51 15 36 15 83 14 93 16 59 17...

Отзывы: